Related Experiment Video For PET/CT
Updated: Apr 24, 2026

Quantitative Immunohistochemistry of the Cellular Microenvironment in Patient Glioblastoma Resections
Published on: July 31, 2017
Somatostatin receptor immunohistochemistry in neuroendocrine tumors: comparison between manual and automated
Daniel Kaemmerer1, Maria Athelogou2, Amelie Lupp3
1Department of General and Visceral Surgery, Zentralklinik Bad Berka Bad Berka, Germany.
Background:
Manual evaluation of somatostatin receptor (SSTR) immunohistochemistry (IHC) is a time-consuming and cost-intensive procedure. Aim of the study was to compare manual evaluation of SSTR subtype IHC to an automated software-based analysis, and to in-vivo imaging by SSTR-based PET/CT.
Methods:
We examined 25 gastroenteropancreatic neuroendocrine tumor (GEP-NET) patients and correlated their in-vivo SSTR-PET/CT data (determined by the standardized uptake values SUVmax,-mean) with the corresponding ex-vivo IHC data of SSTR subtype (1, 2A, 4, 5) expression. Exactly the same lesions were imaged by PET/CT, resected and analyzed by IHC in each patient. After manual evaluation, the IHC slides were digitized and automatically evaluated for SSTR expression by Definiens XD software. A virtual IHC score "BB1" was created for comparing the manual and automated analysis of SSTR expression.
Results:
BB1 showed a significant correlation with the corresponding conventionally determined Her2/neu score of the SSTR-subtypes 2A (rs: 0.57), 4 (rs: 0.44) and 5 (rs: 0.43). BB1 of SSTR2A also significantly correlated with the SUVmax (rs: 0.41) and the SUVmean (rs: 0.50). Likewise, a significant correlation was seen between the conventionally evaluated SSTR2A status and the SUVmax (rs: 0.42) and SUVmean (rs: 0.62).
Conclusion:
Our data demonstrate that the evaluation of the SSTR status by automated analysis (BB1 score), using digitized histopathology slides ("virtual microscopy"), corresponds well with the SSTR2A, 4 and 5 expression as determined by conventional manual histopathology. The BB1 score also exhibited a significant association to the SSTR-PET/CT data in accordance with the high affinity profile of the SSTR analogues used for imaging.
More Related Videos
08:57Author Spotlight: Genetically Engineered Mouse Models and Pathological Characterization of Neurofibromatosis Type 1 Associated Tumors
Published on: May 17, 2024
08:40Quantitation of Protein Expression and Co-localization Using Multiplexed Immuno-histochemical Staining and Multispectral Imaging
Published on: April 8, 2016