Related Experiment Video
Updated: Apr 24, 2026

Tools for the Real-Time Assessment of a Pseudomonas aeruginosa Infection Model
Published on: April 6, 2021
Use of simulation tools to illustrate the effect of data management practices for low and negative plate counts on
Francisco Garcés-Vega1, Bradley P Marks2
1; Department of Biosystems and Agricultural Engineering, Michigan State University, 524 South Shaw Lane, East Lansing, Michigan 48823-1323, USA.
Abstract:
In the last 20 years, the use of microbial reduction models has expanded significantly, including inactivation (linear and nonlinear), survival, and transfer models. However, a major constraint for model development is the impossibility to directly quantify the number of viable microorganisms below the limit of detection (LOD) for a given study. Different approaches have been used to manage this challenge, including ignoring negative plate counts, using statistical estimations, or applying data transformations. Our objective was to illustrate and quantify the effect of negative plate count data management approaches on parameter estimation for microbial reduction models. Because it is impossible to obtain accurate plate counts below the LOD, we performed simulated experiments to generate synthetic data for both log-linear and Weibull-type microbial reductions. We then applied five different, previously reported data management practices and fit log-linear and Weibull models to the resulting data. The results indicated a significant effect (α = 0.05) of the data management practices on the estimated model parameters and performance indicators. For example, when the negative plate counts were replaced by the LOD for log-linear data sets, the slope of the subsequent log-linear model was, on average, 22% smaller than for the original data, the resulting model underpredicted lethality by up to 2.0 log, and the Weibull model was erroneously selected as the most likely correct model for those data. The results demonstrate that it is important to explicitly report LODs and related data management protocols, which can significantly affect model results, interpretation, and utility. Ultimately, we recommend using only the positive plate counts to estimate model parameters for microbial reduction curves and avoiding any data value substitutions or transformations when managing negative plate counts to yield the most accurate model parameters.
Related Concept Videos
Methods to Assess Microbial Communities
Mechanistic Models: Compartment Models in Individual and Population Analysis
Methods of Medium Optimization
Microbial Growth Measurement: Direct Methods
Microbial Growth Measurement: Indirect Methods
Methods to Assess Microbial Populations