Related Experiment Video
Updated: Apr 24, 2026

An Anaerobic Biosensor Assay for the Detection of Mercury and Cadmium
Published on: December 17, 2018
Selecting a sensitive battery of bioassays to detect toxic effects of metals in effluents
Danielly de Paiva Magalhães1, Mônica Regina da Costa Marques2, Darcilio Fernandes Baptista3
1Laboratório de Ecotoxicologia Aplicada à Indústria Mínero-Metalúrgica, CETEM. Av. Pedro Calmon, 900, Ilha da Cidade Universitária, Rio de Janeiro, RJ, CEP 21941-908, Brazil; Laboratório de Tecnologia Ambiental, Instituto de Química, Programa de Pós-graduação em Química, UERJ. R. São Francisco Xavier 524, Maracanã, Rio de Janeiro, RJ, CEP 20550-013, Brazil.
Abstract:
The use of bioassay batteries is necessary to evaluate toxic effects at various biological levels. The selection of bioassays without prior testing and determination of the most sensitive/suitable groups for each impact may allow the discharge of effluents that pose a threat to the environment. The present study tested and selected a battery of sensitive ecotoxicological bioassays for detecting toxic effects of metals. The sensitivities of six organisms were evaluated (algae Pseudokirchneriella subcapitata and Chlorella vulgaris, Cladocera Daphnia similis and Ceriodaphnia dubia, and fish Poecilia reticulata and Danio rerio) after exposure to 10 individual metal species deemed toxic to the aquatic environment (Ag+, Cd2+, Cu+, Cu2+, Cr3+, Cr6+, Pb2+, Ni2+, Zn2+, and Hg2+) and to real (steel-mill) and laboratory simulated effluents. In the bioassays, fish were the least sensitive; D. rerio showed no sensitivity to any of the effluents tested. P. subcapitata was a good bioindicator of Cr3+ toxicity, and D. similis was the most sensitive organism to Hg2+; but the toxic effect of effluents with higher levels of Hg2+ was better detected by C. dubia. The most sensitive battery of bioassays to detect low concentrations of dissolved metals in effluents was the 72-h chronic test with C. vulgaris and the 48-h acute test with C. dubia.
More Related Videos
Related Concept Videos
Toxicity Testing in Animals
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
Microbial Leaching

