Decay mechanisms of protonated 4-quinolone antibiotics after electrospray ionization and ion activation

Borislav Kovačević1, Pascal Schorr, Yulin Qi

  • 1Quantum Chemistry Group, Ruđer Bošković Institute, Zagreb, Croatia.

Insights

Charge isomers of protonated 4-quinolone antibiotics, like ciprofloxacin, exhibit varied behavior in mass spectrometry due to differing formation ratios during electrospray ionization (ESI). This study elucidates their formation and dissociation mechanisms.

Area of Science:

  • Analytical Chemistry
  • Physical Chemistry
  • Computational Chemistry

Background:

  • Piperazinyl quinolones display inconsistent behavior in tandem MS analyses of biological samples.
  • This variability stems from the formation of two isomeric variants during electrospray ionization (ESI).

Purpose of the Study:

  • To investigate the mechanisms of charge isomer formation during ESI for protonated 4-quinolone antibiotics.
  • To elucidate the individual dissociation behaviors of these isomers using advanced analytical techniques.
  • To provide a theoretical framework for understanding isomer formation ratios.

Main Methods:

  • Electrospray ionization-collision-induced dissociation (ESI-CID)
  • Differential ion mobility spectrometry coupled with high-resolution mass spectrometry (DMS-MS)
  • Density functional theory (DFT) calculations

Main Results:

  • DFT calculations revealed a reversal of basicity for piperazinyl quinolones between liquid and gas phases.
  • Experimental and theoretical analyses identified factors influencing isomer formation ratios, including solvent pH and pKa.
  • Separation of isomers by DMS-MS enabled recording of type-specific CID spectra, revealing distinct primary fragmentation pathways (CO2 loss, H2O loss) originating from the carboxyl group.

Conclusions:

  • The study clarifies the formation and dissociation mechanisms of charge isomers in protonated 4-quinolones.
  • Understanding these mechanisms is crucial for accurate analysis of these antibiotics in biological samples.
  • The findings provide a basis for controlling isomer ratios and improving MS-based quantification.

Related Concept Videos

Oxidation of Phenols to Quinones01:17

Oxidation of Phenols to Quinones

In the presence of oxidizing agents, phenols are oxidized to quinones. Quinones can be easily reduced back to phenols using mild reducing agents. The electron-donating hydroxyl group enhances the reactivity of the aromatic ring, enabling oxidation of the ring even in the absence of an α hydrogen.
o-hydroxy phenols are oxidized to o-quinones and p-hydroxy phenols to p-quinones. Such redox reactions involve the transfer of two electrons and two protons. The reversible redox...
4.5K
Chemical Ionization (CI) Mass Spectrometry01:21

Chemical Ionization (CI) Mass Spectrometry

The molecular ion peak of a molecule in the mass spectrum provides vital information for molecular identification. However, conventional electron impact ionization can lead to the rapid dissociation of some molecular ions before they reach the detector. A milder ionization method is required to increase the lifetime of such ionized analyte molecules. Chemical ionization (CI) is a gas-phase protonation reaction useful for mass-analyzing analyte molecules that are easily protonated to yield the...
1.5K
Mass Analyzers: Common Types01:19

Mass Analyzers: Common Types

The quadrupole mass analyzer consists of four cylindrical metal rods arranged in a diamond carrying a DC voltage and a radio-frequency AC voltage. The motion of ions through the quadrupole depends on the field strength, causing only ions of a certain m/z to resonate successfully and strike the detector at a given field strength. Though the transmission rate for these analyzers is high, the exact elemental composition of the sample is not determined because of low resolution; however, they are...
1.9K
Electrospray Ionization (ESI) Mass Spectrometry01:12

Electrospray Ionization (ESI) Mass Spectrometry

Higher molecular weight biomolecules are nonvolatile compounds that may decompose before ionizing or vaporizing during mass analysis with conventional electron impact ionization methods. Accordingly, electrospray ionization (ESI) is the favored method for vaporizing and ionizing biomolecules as it circumvents rapid fragmentation and enables the recording of mass signals for the entire biomolecule.
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
2.6K
Mass Spectrometry: Molecular Fragmentation Overview01:20

Mass Spectrometry: Molecular Fragmentation Overview

The ionization of a molecule into a molecular ion inside the mass spectrometer causes instability in the molecule's structure due to the loss of an electron. This eventually leads to the fragmentation or breaking of some bonds in the molecule. The fragmentation occurs predominantly at specific bonds to yield relatively stable fragments.
One type of fragmentation pattern is the cleavage of a single bond in the molecular ion. The cleavage leads to a radical and a cation. The cleavage can occur at...
5.2K
Ions as Acids and Bases02:54

Ions as Acids and Bases

Salts with Acidic Ions
Salts are ionic compounds composed of cations and anions, either of which may be capable of undergoing an acid or base ionization reaction with water. Aqueous salt solutions, therefore, may be acidic, basic, or neutral, depending on the relative acid-base strengths of the salt’s constituent ions. For example, dissolving the ammonium chloride in water results in its dissociation, as described by the equation:
22.7K