A new tonometric device for radial augmentation index and subendocardial viability ratio: potential use in health
Jing-Zhi Wang1, Yong-Liang Zhang, Fu-Song Hu
1Department of Automation, University of Science and Technology of China, Hefei, China; Research Center for Information Technology of Sports and Health, Institute of Intelligent Machines, Chinese Academy of Sciences, Hefei, China.
Abstract:
Augmentation index (AIx) and subendocardial viability ratio (SEVR) are widely accepted indices of wave reflection and myocardial oxygen demand relative to supply. This study aimed to validate a new tonometric device (IIM-2010A) for obtaining AIx and SEVR from radial artery. A total of 68 outpatients (32 men and 36 women) aged 20 to 76 years (44.7±16.6 years) recruited from a health screening center participated in the study. AIx was obtained from radial pressure using the HEM-9000AI and IIM-2010A devices, while SEVR was measured from carotid pressure with the tonometric method and from radial pressure by the IIM-2010A device. In a subgroup of 24 patients, the measurements of AIx and SEVR were repeated after an interval of 10 minutes. The correlation of radial AIx between the IIM-2010A and HEM-9000AI devices was highly significant (r=0.956, P<.01). Radial SEVR determined from IIM-2010A was also highly related to carotid SEVR (r=0.864, P<.01), although the value was about 13.1% lower. There was no statistically significant difference between the repeated measurements of both indices. The lower coefficient of variation (2.9% vs 4.3% for AIx, 3.3% vs 4.1% for SEVR) and higher intraclass correlation coefficient (0.96 vs 0.91 for AIx, 0.93 vs 0.86 for SEVR) of IIM-2010A confirmed better short-term reproducibility, compared with the HEM-9000AI device and carotid tonometry. The new tonometric device IIM-2010A is effective and reproducible in calculating radial AIx and SEVR and has potential use in health screening.
More Related Videos
07:38Comprehensive Echocardiographic Assessment of Right Ventricle Function in a Rat Model of Pulmonary Arterial Hypertension
Published on: January 20, 2023
08:19Transthoracic Echocardiography to Assess Post-Resuscitation Left Ventricular Dysfunction After Acute Myocardial Infarction and Cardiac Arrest in Pigs
Published on: July 12, 2022
Related Concept Videos
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps: