Thermal Measurement Techniques in Analytical Microfluidic Devices
Published on: June 3, 2015
Rapid dynamic R1 /R2 */temperature assessment: a method with potential for monitoring drug delivery
Cyril Lorenzato1, Chris Oerlemans, Alexandru Cernicanu
1University Medical Center Utrecht, Department of Radiology, Imaging Division, Heidelberglaan 100, 3584, CX, Utrecht, the Netherlands.
Abstract:
Local drug delivery by hyperthermia-induced drug release from thermosensitive liposomes (TSLs) may reduce the systemic toxicity of chemotherapy, whilst maintaining or increasing its efficacy. Relaxivity contrast agents can be co-encapsulated with the drug to allow the visualization of the presence of liposomes, by means of R2 *, as well as the co-release of the contrast agent and the drug, by means of R1, on heating. Here, the mathematical method used to extract both R2 * and R1 from a fast dynamic multi-echo spoiled gradient echo (ME-SPGR) is presented and analyzed. Finally, this method is used to monitor such release events. R2 * was obtained from a fit to the ME-SPGR data. Absolute R1 was calculated from the signal magnitude changes corrected for the apparent proton density changes and a baseline Look-Locker R1 map. The method was used to monitor nearly homogeneous water bath heating and local focused ultrasound heating of muscle tissue, and to visualize the release of a gadolinium chelate from TSLs in vitro. R2 *, R1 and temperature maps were measured with a 5-s temporal resolution. Both R2 *and R1 measured were found to change with temperature. The dynamic R1 measurements after heating agreed with the Look-Locker R1 values if changes in equilibrium magnetization with temperature were considered. Release of gadolinium from TSLs was detected by an R1 increase near the phase transition temperature, as well as a shallow R2 * increase. Simultaneous temperature, R2 * and R1 mapping is feasible in real time and has the potential for use in image-guided drug delivery studies.
Related Concept Videos
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Therapeutic Drug Monitoring: Drug Analysis Methods
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Modified-Release Drug Delivery Systems: Rate-Programmed I
Methods for Studying Drug Absorption: In situ
The Doluisio method involves perfusing a prepared segment of a rat's small intestine with a solution of radiolabeled drug and a non-absorbable marker. This helps to differentiate between absorbed and non-absorbed drug concentrations. The intestinal segment is connected at both ends using tubing and syringes,...
Measurement of Bioavailability: Pharmacodynamic Methods