Related Experiment Video
Updated: Apr 24, 2026

Continuous Venous-Arterial Doppler Ultrasound During a Preload Challenge
Published on: January 20, 2023
Pulse pressure variation is not a valid predictor of fluid responsiveness in patients with elevated left ventricular
Jae-Kwang Shim1, Jong-Wook Song1, Young Song1
1Department of Anesthesiology and Pain Medicine, Yonsei University Health System, Seoul, 120-752, South Korea; Anesthesia and Pain Research Institute, Yonsei University Health System, Seoul, 120-752, South Korea.
Purpose:
The purpose of this study was to test the hypothesis that the predictive ability of pulse pressure variation (PPV) for fluid responsiveness would be altered in patients with elevated left ventricular (LV) filling pressure.
Materials And Methods:
According to the preoperative echocardiographic assessment of the ratio of early transmitral flow velocity to early diastolic velocity of the mitral annulus (E/E'), patients undergoing surgical coronary revascularization were classified into normal (n=34, E/E'<8) and high (n=34, E/E'>15) LV filling pressure group. After anesthetic induction, PPV and hemodynamic data were measured before and after 6 mL/kg of colloid administration. Fluid responsiveness was defined as 12% or more increase in stroke volume index assessed by pulmonary artery catheter and tested by the area under the receiver operating characteristic curve (AUROC).
Results:
The AUROCs of PPV in the normal and high filling pressure group were 0.829 (95% confidence interval [CI], 0.661-0.963; P<.001) and 0.583 (95% CI, 0.402-0.749; P=.110), respectively. The AUROCs of cardiac filling pressures and right ventricular end-diastolic volume index did not show statistical significance in both groups.
Conclusions:
None of the assessed preload indices including PPV were able to predict fluid responsiveness in patients with elevated LV filling pressure.
More Related Videos
Related Concept Videos
Measurement of Blood Pressure
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Blood Pressure
Blood Pressure
The average BP in an adult is typically around 120/80 mmHg (millimeters of mercury). In this measurement, the numerator (120) indicates the systolic pressure, which is the pressure in the arteries during the contraction of the heart's ventricles as blood is expelled. The denominator (80) represents the...
Measurement of Fluid Pressure
A basic form of manometer is the piezometer, a vertical tube open at the top and filled with the same...