Related Experiment Video
Updated: Apr 24, 2026

A Strategy for Sensitive, Large Scale Quantitative Metabolomics
Published on: May 27, 2014
Multi-drug and metabolite quantification in postmortem blood by liquid chromatography-high-resolution mass
Thomas G Rosano1, Seo Na2, Kenneth Ihenetu3
1Forensic Toxicology Laboratory, Department of Pathology and Laboratory Medicine, Albany Medical Center Hospital and College, 43 New Scotland Avenue, Albany, NY 12208, USA rosanot@mail.amc.edu.
Abstract:
High-resolution mass spectrometry (HRMS) is being applied in postmortem drug screening as an alternative to nominal mass spectrometry, and additional evaluation in quantitative casework is needed. We report quantitative analysis of benzoylecgonine, citalopram, cocaethylene, cocaine, codeine, dextromethorphan, dihydrocodeine, diphenhydramine, 2-ethylidene-1,5-dimethyl-3,3-diphenylpyrrolidine, hydrocodone, hydromorphone, meperidine, methadone, morphine, oxycodone and oxymorphone in postmortem blood by ultra-performance liquid chromatography (UPLC)-MS(E)/time-of-flight (TOF). The method employs analyte-matched deuterated internal standardization and MS(E) acquisition of precursor and product ions at low (6 eV) and ramped (10-40 eV) collision energies, respectively. Quantification was performed using precursor ion data obtained with a mass extraction window of ± 5 ppm. Fragment and residual precursor ion acquisitions at ramped collision energies were evaluated as additional analyte identifiers. Extraction recovery of >60% and matrix effect of <20% were determined for all analytes and internal standards. Defined limits of detection (10 ng/mL) and quantification (25 ng/mL) were validated along with a linearity analytical range of 25-3,000 ng/mL (R(2) > 0.99) for all analytes. Parallel UPLC-MS(E)/TOF and UPLC-MS/MS analysis showed comparable precision and bias along with concordance of 253 positive (y = 1.002x + 1.523; R(2) = 0.993) and 2,269 negative analyte findings in 159 postmortem cases. Analytical performance and correlation studies demonstrate accurate quantification by UPLC-MS(E)/TOF and extended application of HRMS in postmortem casework.
More Related Videos
11:00Untargeted Metabolomics from Biological Sources Using Ultraperformance Liquid Chromatography-High Resolution Mass Spectrometry UPLC-HRMS
Published on: May 20, 2013
10:17High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
Related Concept Videos
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
High-Performance Liquid Chromatography: Types of Detectors