Related Experiment Video
Updated: Apr 24, 2026

A Novel Rescue Technique for Difficult Intubation and Difficult Ventilation
Published on: January 17, 2011
Techniques to ascertain correct endotracheal tube placement in neonates
Georg M Schmölzer1, Charles C Roehr
1Department of Pediatrics, Division of Neonatology, University of Alberta, Royal Alexandra Hospital, Rm. 418 CSC, 10240 Kingsway Ave, Edmonton, AB, Canada, T5H 3V9.
Background:
The success rate of correct endotracheal tube (ETT) placement for junior medical staff is less than 50% and accidental oesophageal intubation is common. Rapid confirmation of correct tube placement is important because tube malposition is associated with serious adverse outcomes including hypoxaemia, death, pneumothorax and right upper lobe collapse.ETT position can be confirmed using chest radiography, but this is often delayed; hence, a number of rapid point-of-care methods to confirm correct tube placement have been developed. Current neonatal resuscitation guidelines advise that correct ETT placement should be confirmed by the observation of clinical signs and the detection of exhaled carbon dioxide (CO2). Even though these devices are frequently used in the delivery room to assess tube placement, they can display false-negative results. Recently, newer techniques to assess correct tube placement have emerged (e.g. respiratory function monitor), which have been claimed to be superior in the assessment of tube placement.
Objectives:
To assess various techniques for the identification of correct ETT placement after oral or nasal intubation in newborn infants in either the delivery room or neonatal intensive care unit compared with chest radiography.
Search Methods:
We searched the Cochrane Central Register of Controlled Trials (CENTRAL,The Cochrane Library 2012, Issue 4), MEDLINE (January 1996 to June 2014), EMBASE (January 1980 to Juen 2014) and CINAHL (January 1982 to June 2014). We searched clinical trials registers and the abstracts of the Society for Pediatric Research and the European Society for Pediatric Research from 2004 to 2014. We did not apply any language restrictions.
Selection Criteria:
We planned to include randomised and quasi-randomised controlled trials and cluster trials that compared chest radiography with clinical signs, respiratory function monitors, exhaled CO2 detectors or ultrasound for the assessment of correct ETT placement either in the delivery room or the neonatal intensive care unit.
Data Collection And Analysis:
Two review authors independently evaluated the search results against the selection criteria. We did not perform data extraction and 'Risk of bias' assessments because we identified no studies that met our inclusion criteria.
Main Results:
We did not identify any studies meeting the criteria for inclusion in this review.
Authors' Conclusions:
There is insufficient evidence to determine the most effective technique for the assessment of correct ETT placement either in the delivery room or the neonatal intensive care unit. Randomised clinical trials comparing either of these techniques with chest radiography are warranted.
Related Concept Videos
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Endotracheal Intubation II: Nursing Management
1. Nursing Care of Patients Before Intubation
Before the endotracheal intubation procedure, nurses play an essential role in ensuring the process goes smoothly. The nurses must be familiar with intubation...
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...
Tracheostomy Care II: Procedure
Step 1: Perform hand hygiene, and put on personal protective equipment: gown, gloves, mask...
Endoscopic Studies II: Thoracocentesis
Description
Excess pleural fluid or air may accumulate in some respiratory disorders in the thoracic cavity. To treat pleural effusion, a physician conducts thoracentesis by carefully piercing the chest wall and entering...

