Transcatheter Pulmonary Valve Replacement from Autologous Pericardium with a Self-Expandable Nitinol Stent in an Adult Sheep Model
Published on: June 8, 2022
Results of transcatheter pulmonary valvulation in native or patched right ventricular outflow tracts
Sophie Malekzadeh-Milani1, Magalie Ladouceur1, Sarah Cohen1
1Centre de référence malformations cardiaques congénitales complexes - M3C, Necker Hospital for Sick Children, Georges-Pompidou European Hospital, Assistance Publique des Hopitaux de Paris, Paediatric Cardiology, Paris, France.
Background:
Although widely accepted worldwide, indications for percutaneous valve replacement are limited to treatment of dysfunction of prosthetic conduits inserted in the right ventricular outflow tract (RVOT). There has been little evaluation of the use of the Melody(®) valve for patched non-circular pulmonary pathways.
Aim:
To evaluate the outcomes of Melody valve insertion in patients with a patched non-circular RVOT.
Methods:
We analysed procedural and outcomes data from 34 patients who underwent Melody valve implantation for a non-circular RVOT. RVOT preparation was done in all patients, using different techniques (conventional, Russian doll and/or PA jailing). Melody valve insertion was performed concomitantly in most patients.
Results:
All procedures were successful. Sixteen patients had complex additional procedures, including the jailing technique (n=5), the Russian doll technique (n=6) and multiple stent implantations (Russian jailing; n=5). The remaining patients were treated using the conventional technique with systematic prestenting. Three early complications occurred: one haemoptysis; one residual RVOT obstruction needing recatheterization 48 hours after percutaneous pulmonary valve implantation; and one stent embolization during advancement of the Ensemble(®) delivery system. The mean follow-up period was 2.6 years postprocedure. There was no stent fracture, migration or embolization. Two patients developed a significant paraprosthetic leak and one received a second Melody valve.
Conclusions:
Careful patient selection, balloon sizing and RVOT preparation with prestenting are required to create a safe landing zone for the Melody valve. Short-term follow-up shows excellent results with no stent fracture or migration and appears promising.
More Related Videos
09:57Four-Dimensional Computed Tomography-Guided Valve Sizing for Transcatheter Pulmonary Valve Replacement
Published on: January 20, 2022
09:40Induction of Right Ventricular Failure by Pulmonary Artery Constriction and Evaluation of Right Ventricular Function in Mice
Published on: May 13, 2019
Related Concept Videos
Cardiac Catheterization II: Right Heart Catheterization
Mitral Stenosis III: Medical Management