The influence of positive end-expiratory pressure on stroke volume variation in patients undergoing cardiac surgery:
Woon-Seok Kang1, Seong-Hyop Kim1, Sung Yun Kim2
1Department of Anesthesiology and Pain Medicine, Konkuk University Medical Center, Konkuk University School of Medicine, Seoul, Korea; Institute of Biomedical Science and Technology, Konkuk University School of Medicine, Seoul, Korea.
Objectives:
Measurements of stroke volume variation for volume management in mechanically ventilated patients are influenced by various factors, such as tidal volume, respiratory rate, and chest/lung compliance. However, research regarding the effect of positive end-expiratory pressure on stroke volume variation is limited.
Methods:
Patients were divided into responder and nonresponder groups according to the prediction of fluid response by the passive leg raising test and hemodynamic parameters, including stroke volume variation, measured in all patients at the following ventilator settings: (1) conventional ventilation (C), tidal volume 10 mL · kg(-1) with positive end-expiratory pressure settings of 0 (C0), 5 (C5), and 10 cmH2O (C10) and (2) lung protective ventilation (P), tidal volume 6 mL · kg(-1) with positive end-expiratory pressure settings of 0 (P0), 5 (P5), and 10 cmH2O (P10).
Results:
Regardless of ventilator setting, stroke volume variation in the responder group had an increasing trend as increased positive end-expiratory pressure level and was significantly higher than in the nonresponder group at each positive end-expiratory pressure level. The area under the curve was (1) 0.899 at C0, 0.942 at C5, and 0.985 at C10; and (2) 0.901 at P0, 0.932 at P5, and 0.947 at P10. Optimal threshold values given by receiver operating characteristic curve analysis were (1) 13.5%, 13.5%, and 14.5%; and (2) 13.5%, 13.5%, and 14.5%, respectively.
Conclusions:
The threshold value of stroke volume variation in predicting fluid responsiveness may change when positive end-expiratory pressure 10 cmH2O is applied. This must be considered when stroke volume variation is used to detect the fluid responsiveness to prevent volume overload in this mechanical ventilation setting.
Related Concept Videos
Regulation of Stroke Volume
Preload refers to the degree of stretch on the heart before it contracts. It's analogous to the stretching of a rubber band; the more it's stretched, the more forcefully it snaps back. This concept is encapsulated in the Frank-Starling law of the...
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Mechanical Ventilation I: Indication and Settings
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...