Related Experiment Video
Updated: Apr 23, 2026

A Model to Simulate Clinically Relevant Hypoxia in Humans
Published on: December 22, 2016
Blood oxygen equilibration time after cessation of supplemental oxygen in chronic respiratory disease
A M C Stone1, K K H Wong, D J Barnes
1Department of Respiratory and Sleep Medicine, Royal Prince Alfred Hospital, Sydney, New South Wales, Australia.
Background:
Measurement of the arterial partial pressure of oxygen (PaO2 ) while breathing air is an informative investigation in patients with hypoxaemia due to chronic respiratory disease, but there are a lack of published data on the time needed for blood oxygen levels to equilibrate after cessation of supplemental oxygen (O2 ) in such patients.
Aim:
To determine the blood oxygen equilibration time after cessation of O2 and thereby provide guidance on best timing of baseline arterial blood gas analysis in this population.
Methods:
Medically stable subjects with chronic respiratory disease were administered O2 at a constant concentration. Continuous pulse oximetry was recorded from before cessation of O2 to beyond the point of oxygen saturation (SpO2 ) equilibration. Data were fitted to an exponential decay model. Blood oxygen equilibration time was defined as the t90, the time taken for SpO2 to fall 90% of the difference between initial (on O2 ) and final (on air) values.
Results:
Eighty-two (82) subjects with a mean age of 66 years were included. The largest diagnostic category was chronic obstructive pulmonary disease (37), followed by interstitial lung disease (15) and bronchiectasis (12). The median t90 was 6 min 18 s (interquartile range: 4 min 32 s-10 min 30 s). The 95th centile t90 value was 20 min.
Conclusion:
In the majority of patients with chronic respiratory disease, a time delay of 20 min between cessation of supplemental O2 and PaO2 measurement allows confidence that the result is a true baseline value.
More Related Videos
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
08:44Author Spotlight: Integrating Alveolar-Capillary Reserve Measurements in Exercise Adaptation and Therapeutic Strategies
Published on: February 2, 2024
Related Concept Videos
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Acute Respiratory Failure-II
The underlying physiological abnormalities that contribute to hypoxemic respiratory failure include:
Acute Respiratory Failure-IV
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Acute Respiratory Failure-I
Definition: It is defined by specific criteria based on blood gas measurements. Hypoxemia happens when the partial pressure of oxygen (PaO2) falls below 60 mmHg. At the same time,...
Pulse Oximetry
Purpose