In Vitro Model of Physiological and Pathological Blood Flow with Application to Investigations of Vascular Cell Remodeling
Published on: November 3, 2015
Influence of compliance on flow rate waveforms in hydraulic circuits for in vitro modeling the human circulatory
Wenbo He1, Yuan Wang1, Xiaoyan Gong1
1School of Energy and Power Engineering, Xi'an Jiaotong University, Xi'an 710049, Shaanxi, China.
Abstract:
Generating an artificial blood flow in a circle system is an important step in hemodynamic research; thus, the influence of circle system components on the pulsatile flow wave forms should be investigated. In this study, a circle system was built, in which two solenoid valves were controlled by a timer to transform a constant flow into a pulsatile one, and two customized compliances with five different aeration volumes were set up upstream and downstream of the test chamber, achieving twenty-five different wave forms. Then, the influence of the compliance settings on the flow rate wave form was investigated. From the experimental data, it can be concluded that the absolute value of the maximum value and the minimum value of the wave forms increases along the aeration of the downstream compliance but decreases along the aeration of the upstream compliance. For the second maximum value and the offset between the maximum value and the minimum value, remarkable differences were obtained between runs with aeration of zero compliance and nonzero compliance. Finally, an emulational flow was achieved with the up- and downstream aeration volume equaling 360 mL and 180 mL, respectively, which fit the realistic wave form well.
Related Concept Videos
Typical Model Studies
Design Example: Creating a Hydraulic Model of a Dam Spillway
Rapidly Varying Flow
Applications of Integration to Find Blood Flow
Autoregulation of Blood Flow
Chemical Signaling in Autoregulation
Chemical signaling operates at the precapillary sphincter level, inciting either contraction or relaxation....