Related Experiment Video
Updated: Apr 23, 2026

Murine Echocardiography of Left Atrium, Aorta, and Pulmonary Artery
Published on: February 20, 2017
Best method for right atrial volume assessment by two-dimensional echocardiography: validation with magnetic
Mahasti Ebtia1, Darra Murphy, Kenneth Gin
1Vancouver General and University of British Columbia Hospital Echocardiography Laboratory, Division of Cardiology, University of British Columbia, Vancouver, British Columbia, Canada.
Aim:
Echocardiographic methods for estimating right atrial (RA) volume have not been standardized. Our aim was to evaluate two-dimensional (2D) echocardiographic methods of RA volume assessment, using RA volume by magnetic resonance imaging (MRI) as the reference.
Methods And Results:
Right atrial volume was assessed in 51 patients (mean age 63 ± 14 years, 33 female) who underwent comprehensive 2D echocardiography and cardiac MRI for clinically indicated reasons. Echocardiographic RA volume methods included (1) biplane area length, using four-chamber view twice (biplane 4C-4C); (2) biplane area length, using four-chamber and subcostal views (biplane 4C-subcostal); and (3) single plane Simpson's method of disks (Simpson's). Echocardiographic RA volumes as well as linear RA major and minor dimensions were compared to RA volume by MRI using correlation and Bland-Altman methods, and evaluated for inter-observer reproducibility and accuracy in discriminating RA enlargement. All echocardiography volumetric methods performed well compared to MRI, with Pearson's correlation of 0.98 and concordance correlation ≥0.91 for each. For bias and limits of agreement, biplane 4C-4C (bias -4.81 mL/m(2) , limits of agreement ±9.8 mL/m(2) ) and Simpson's (bias -5.15 mL/m(2) , limits of agreement ±10.1 mL/m(2) ) outperformed biplane 4C-subcostal (bias -8.36 mL/m(2) , limits of agreement ±12.5 mL/m(2) ). Accuracy for discriminating RA enlargement was higher for all volumetric methods than for linear measurements. Inter-observer variability was satisfactory across all methods.
Conclusions:
Compared to MRI, biplane 4C-4C and single plane Simpson's are highly accurate and reproducible 2D echocardiography methods for estimating RA volume. Linear dimensions are inaccurate and should be abandoned.
More Related Videos
08:10Estimating Bilateral Atrial Function by Cardiovascular Magnetic Resonance Feature Tracking in Patients with Paroxysmal Atrial Fibrillation
Published on: July 20, 2022
07:11Morphological and Functional Assessment of the Right Ventricle Using 3D Echocardiography
Published on: October 28, 2020