Related Experiment Video
Updated: Apr 23, 2026

Curtain Flow Column: Optimization of Efficiency and Sensitivity
Published on: June 12, 2016
Comparison and optimization of different peak integration methods to determine the variance of unretained and
Yoachim Vanderheyden1, Ken Broeckhoven1, Gert Desmet1
1Vrije Universiteit Brussel, Department of Chemical Engineering, Pleinlaan 2, 1050 Brussels, Belgium.
Abstract:
Different automatic peak integration methods have been reviewed and compared for their ability to accurately determine the variance of the very narrow and very fast eluting peaks encountered when measuring the instrument band broadening of today's low dispersion liquid chromatography instruments. Using fully maximized injection concentrations to work at the highest possible signal-to-noise ratio's (SNR), the best results were obtained with the so-called variance profile analysis method. This is an extension (supplemented with a user-independent read-out algorithm) of a recently proposed method which calculates the peak variance value for any possible value of the peak end time, providing a curve containing all the possible variance values and theoretically levelling off to the (best possible estimate of the) true variance. Despite the use of maximal injection concentrations (leading to SNRs over 10,000), the peak variance errors were of the order of some 10-20%, mostly depending on the peak tail characteristics. The accuracy could however be significantly increased (to an error level below 0.5-2%) by averaging over 10-15 subsequent measurements, or by first adding the peak profiles of 10-15 subsequent runs and then analyzing this summed peak. There also appears to be an optimal detector intermediate frequency, with the higher frequencies suffering from their poorer signal-to-noise-ratio and with the smaller detector frequencies suffering from a limited number of data points. When the SNR drops below 1000, an accurate determination of the true variance of extra-column peaks of modern instruments no longer seems to be possible.
More Related Videos
05:29Profiling Volatile Compounds in Blackcurrant Fruit using Headspace Solid-Phase Microextraction Coupled to Gas Chromatography-Mass Spectrometry
Published on: June 9, 2021
10:14Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
Related Concept Videos
¹H NMR Signal Integration: Overview
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
Chromatographic Resolution
The effectiveness of separation can be evaluated by determining the level of separation between two neighboring peaks in a chromatogram, which represents the individual components of a sample.
In chromatography,...
Chromatographic Methods: Terminology
Column Efficiency: Rate Theory
During elution, a solute molecule experiences numerous transitions between stationary and mobile phases, exhibiting irregular residence times in...
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences