Minimally invasive percutaneous plate osteosynthesis for closed distal tibial fractures: a consecutive study based on
Rafiq Bhat1, Mubashir Maqbool Wani, Shakir Rashid
1Department of Orthopaedics, Government Medical College Srinagar (Hospital for bone and joint surgery Barzulla), Srinagar, 190005, India.
Abstract:
We studied the outcome of minimally invasive percutaneous plate osteosynthesis (MIPPO) using locking plate for closed fractures of distal tibia in a consecutive study consisting of 25 patients. Preoperative variables were age of patient, mode of trauma, type of fracture, and soft tissue status. Postoperative variables included wound status, time to union, return to activity, and AO foot and ankle score. After 1 year, all the fractures had united. The average time to union was 16.8 weeks. There were two cases of superficial infection. We also had two cases of deep infection, which required removal of hardware after the fracture was united. The average AO foot and ankle score was 83.6 in our study. We concluded that using MIPPO is a safe and effective method for the treatment for distal tibial fractures in properly selected patients.
More Related Videos
07:35Creating Rigidly Stabilized Fractures for Assessing Intramembranous Ossification, Distraction Osteogenesis, or Healing of Critical Sized Defects
Published on: April 11, 2012
06:38Establishment of a Segmental Femoral Critical-size Defect Model in Mice Stabilized by Plate Osteosynthesis
Published on: October 12, 2016