The concordance between nonclinical and phase I clinical cardiovascular assessment from a cross-company data sharing initiative
Related Experiment Video
Updated: Apr 23, 2026

Author Spotlight: Exercise Test for Evaluation of the Functional Efficacy of the Pig Cardiovascular System
Published on: May 12, 2023
Lorna Ewart1, Mike Aylott2, Mark Deurinck2
1*AstraZeneca R&D Mölndal, Pepparedsleden 1, 431 83, Mölndal, Sweden, GlaxoSmithKline, Park Road, Ware, Hertfordshire, SG12 ODP, UK, Novartis Pharma AG, PO Box, CH-4002, Basel, Switzerland, Amgen, Inc, One Amgen Center Drive, Thousand Oaks, CA 91320, Janssen Research & Development, a division of Janssen Pharmaceutica NV, Turnhoutseweg 30, B-2340 Beerse, Belgium, Novartis Institutes for BioMedical Research, One Health Plaza, East Hanover, NJ 07936, Eli Lilly and company, Indianapolis, IN 46285, Association of the British Pharmaceutical Industry, 105 Victoria Street, London SW1E 6QT, UK, Pfizer Inc., Eastern Point Road, Groton, CT 06340 and Safety Pharmacology consultant, Sandwich, Kent, UK lorna.ewart@astrazeneca.com.
Abstract:
It is widely accepted that more needs to be done to bring new, safe, and efficacious drugs to the market. Cardiovascular toxicity detected both in early drug discovery as well as in the clinic, is a major contributor to the high failure rate of new molecules. The growth of translational safety offers a promising approach to improve the probability of success for new molecules. Here we describe a cross-company initiative to determine the concordance between the conscious telemetered dog and phase I outcome for 3 cardiovascular parameters. The data indicate that, in the context of the methods applied in this analysis, the ability to detect compounds that affect the corrected QT interval (QTc) was good within the 10-30x exposure range but the predictive or detective value for heart rate and diastolic blood pressure was poor. These findings may highlight opportunities to refine both the animal and the clinical study designs, as well as refocusing the assessment of value of dog cardiovascular assessments beyond phase 1. This investigation has also highlighted key considerations for cross-company data sharing and presents a unique learning opportunity to improve future translational projects.
More Related Videos
04:05Author Spotlight: Unveiling Prognostic Indicators in Heart Failure - The Role of Phase Angle and Bioelectrical Impedance Analysis
Published on: June 30, 2023
07:42Contractions of Human-iPSC-derived Cardiomyocyte Syncytia Measured with a Ca-sensitive Fluorescent Dye in Temperature-controlled 384-well Plates
Published on: October 18, 2018
Related Concept Videos
Clinical Trials: Overview
Clinical Trials
There are four phases in a clinical trial. A phase one...
Assessment of the Cardiovascular System I: Subjective Data
Initial Enquiry
Ask the patient about their primary concern and thoroughly explore all reported symptoms.
Medical History
Investigate past illnesses affecting the cardiovascular system, such as angina, anemia, rheumatic fever, congenital heart disease, stroke, thrombophlebitis, dysrhythmias, varicosities
Inquire about symptoms...
Preclinical Development: Overview
Cardiovascular Drugs: Classification based on Therapeutic Indications
Assessment of the Cardiovascular System IV: Auscultation
Normal Heart Sounds
S1 (First Heart Sound)-
S1 is made by the closure of the mitral and tricuspid valves (atrioventricular valves), marking the beginning of systole.
S2 (Second Heart Sound)-
S2 is made by the closure of the aortic and pulmonic valves (semilunar valves), marking the end of the systole.