Prevalence of Bacterial Contamination when using a Diversion Pouch during Blood Collection: A Single Center Study in

Norlaili Jumaah1, Sanmukh Ratilal Joshi1, Doblin Sandai1

  • 1Advanced Medical and Dental Institute, Universiti Sains Malaysia, Bertam 13200 Kepala Batas, Penang, Malaysia.

Abstract

Insights

Diversion pouches significantly reduce bacterial contamination during blood collection. This study found only 1.7% contamination in diversion pouches, highlighting their importance in transfusion safety.

Area of Science:

  • Transfusion Medicine
  • Microbiology
  • Infection Control

Background:

  • Bacterial contamination is a risk in blood collection.
  • Diversion pouches aim to minimize this risk by diverting initial blood flow.
  • This study assessed contamination rates in diversion pouches at Hospital Seberang Jaya.

Purpose of the Study:

  • To determine the prevalence of bacterial contamination in diversion pouches.
  • To evaluate the effectiveness of diversion pouches in preventing contamination during blood collection.

Main Methods:

  • 702 blood samples collected in diversion pouches were analyzed.
  • BD Bactec™ Fx instrument detection system was used for bacterial detection.
  • Positive samples were subcultured to identify bacterial species.

Main Results:

  • A low contamination rate of 1.7% (12 out of 702 samples) was observed.
  • Identified bacterial contaminants included coagulase-negative Staphylococcus, Staphylococcus aureus, and Gram-positive Bacilli.

Conclusions:

  • The use of diversion pouches is crucial for reducing bacterial contamination in blood collection.
  • Diversion pouches play a significant role in enhancing transfusion safety.