Related Experiment Video
Updated: Apr 23, 2026

Electrophysiological Assessment of Murine Atria with High-Resolution Optical Mapping
Published on: February 22, 2018
Electrophysiological changes preceding the onset of atrial fibrillation after coronary bypass grafting surgery
Feng Xiong1, Yalin Yin2, Bruno Dubé3
1Research Center, Hôpital du Sacré-Cœur de Montréal, Université de Montréal, Montréal, Canada; Montréal Heart Institute, Université de Montréal, Montréal, Canada.
Background:
The incidence of Post-CABG atrial fibrillation (AF) lies between 25% and 40%. It worsens morbidity and raises post-operative costs. Detection of incoming AF soon enough for prophylactic intervention would be helpful. The study is to investigate the electrophysiological changes preceding the onset of AF and their relationship to the preoperative risk.
Methods And Results:
Patients were recorded continuously for the first four days after coronary artery bypass grafting surgery (CABG) with three unipolar electrodes sutured to the atria (AEG). The patients experiencing an AF lasting more than 10 minutes were selected and the two hours before the onset were analyzed. Four variables were found to show significant changes in the two hours prior to the first prolonged AF: increasing rate of premature atrial activation, increasing incidence of short transient arrhythmias, acceleration of heart rate, and rise of low frequency content of heart rate. The main contrast was between the first and last hour before AF onset. Preoperative risk was not predictive of the onset time of AF and did not correlate with the amplitude of changes prior to AF.
Conclusions:
Post-CABG AF were preceded by electrophysiological changes occurring in the last hour before the onset of the arrhythmia, whereas none of these changes was found to occur in all AF patients. The risk was a weighted sum of factors related to the density of premature activations and the state of atrial substrate reflected by the sinus rhythm and its frequency content prior to AF. Preoperative risk score seems unhelpful in setting a detection threshold for the AF onset.
Related Concept Videos
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias
Dysrhythmias IV: Characteristics of Bradyarrhythmias
Acute Coronary Syndrome III: Diagnostic Studies
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Electrophysiology of Normal Cardiac Rhythm
Disturbances in Heart Rhythm
Arrhythmias are categorized by their speed, rhythm, and origin. A slow heart...

