Cardiac output monitoring: a contemporary assessment and review
Robert H Thiele1, Karsten Bartels, Tong J Gan
11Department of Anesthesiology, University of Virginia, Charlottesville, VA. 2Department of Anesthesiology, University of Colorado Denver, Aurora, CO. 3Department of Anesthesiology, Stony Brook University, Stony Brook, NY.
Objective:
An increasing number of minimally or noninvasive devices are available to measure cardiac output in the critical care setting. This article reviews the underlying physical principles of these devices in addition to examining both animal and human comparative studies in an effort to allow clinicians to make informed decisions when selecting a device to measure cardiac output.
Data Sources:
Peer-reviewed manuscripts indexed in PubMed.
Study Selection:
A systematic search of the PubMed database for articles describing the use of cardiac output monitors yielded 1,526 sources that were included in the analysis.
Data Extraction:
From all published cardiac output monitoring studies reviewed, the animal model, number of independent measurements, and correlation between techniques was extracted.
Data Synthesis:
Comparative studies in animals and humans between devices designed for measurement of cardiac output and experimental reference standards indicate thermodilution and Doppler-based techniques to have acceptable accuracy across a wide range of hemodynamic conditions, with bioimpedance techniques being less accurate. Thermodilution devices are marginally more accurate than Doppler-based devices but suffer from slower response time, increased invasiveness, and require stable core temperatures, good operator technique, and a competent tricuspid valve. Doppler-based techniques are less invasive and offer beat-to-beat measurements and excellent trending ability, but are dependent on accurate beam alignment and knowledge of aortic cross-sectional area. Studies of newer devices, such as pulse contour analysis, partial rebreathing, and pulse wave velocity, are far less in number and are primarily based on comparisons with thermodilution-based cardiac output measurements. Studies show widely ranging results.
Conclusion:
Thermodilution is relatively accurate for cardiac output measurements in both animals and humans when compared to experimental reference standards. Doppler-based techniques appear to have similar accuracy as thermodilution pulmonary artery catheters. Bioimpedance, pulse contour, partial rebreathing, and pulse wave velocity-based devices have not been studied as rigorously; however, the majority of studies included in this analysis point towards decreased accuracy.
More Related Videos
06:10Author Spotlight: Assessment of Cardiac Output Calculation by Thermodilution in Pigs for Effective Perfusion Flow During EVLP
Published on: June 28, 2024
08:49Author Spotlight: Enhancing Graft Viability Assessment Through Quantitative Metrics and Innovative Reservoir Systems
Published on: August 2, 2024
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Cardiac Output and Stroke Volume
In an average resting adult male, the typical cardiac...
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart...
Imbalances in Cardiac Output
CHF can occur due to the failure of either side of the heart. Left-side failure leads to pulmonary congestion—the right side continues to send...
Exercise and Cardiac Output