Related Experiment Video
Updated: Apr 23, 2026

Two-Dimensional Visualization and Quantification of Labile, Inorganic Plant Nutrients and Contaminants in Soil
Published on: September 1, 2020
Quantitative assessment of the distribution of dissolved Au, As and Sb in groundwater using the diffusive gradients
Andrew R Lucas1, Nathan Reid, S Ursula Salmon
1School of Earth and Environment, University of Western Australia , 35 Stirling Highway, Crawley 6009, Western Australia, Australia.
Abstract:
The mobility of groundwater and its reactivity with subsurface lithologies makes it an ideal medium for investigating both the mineralogy of the extensive volume of the rocks and soils that it comes into contact with, including the distribution of potential commodities, and the presence of contaminants. Groundwater grab sampling is potentially an effective tool for evaluating metal and metalloid concentrations but can suffer from poor replication and high detection limits. This study evaluates the diffusive gradients in thin films (DGT) technique to detect signatures of Au mineralization in groundwater, as well as associated pathfinder and potential contaminant elements (As and Sb). The DGT technique was modified for Au by evaluating a "gel-less" configuration, with diffusion onto an activated carbon binding layer being controlled by the 0.13 mm thick filter membrane (0.45 μm porosity) only, in order to increase sensitivity in quiescent solutions. Laboratory-based measurements indicated that the diffusive boundary layer (DBL) was ∼ 0.40 mm in thickness in quiescent solutions. The modified DGT samplers were then deployed alongside ferrihydrite DGT devices (fitted with 0.8 mm diffusive gels) to simultaneously measure Au, As and Sb in groundwaters surrounding a known arsenopyrite-hosted Au ore body. DGT-measured Au concentrations ranged from 2.0 ng/L to 38.5 ng/L, and were within a factor of 5 of grab sample concentrations. DGT-measured concentrations of As and Sb were above the detection limits, while grab sample concentrations of As and Sb were often close to or below detection. The DGT technique demonstrated methodological improvement over grab sampling of groundwater for the investigated elements with respect to sensitivity, replication, and portability, although DGT requires further evaluation in a wider range of groundwater environments and conditions.
More Related Videos
12:22Speciation and Bioavailability Measurements of Environmental Plutonium Using Diffusion in Thin Films
Published on: November 9, 2015
09:51TD-DFT Guided Advanced E-Eye Sensing Technique for On-site Quantification of Fe, Cr, F, and As in the Environmental, Biological, and Food Samples
Published on: September 19, 2025
Related Concept Videos
Gravimetry: Overview
In precipitation gravimetry, the analyte is converted into a precipitate and weighed. For example, the silver content in a sample can be estimated by precipitating and...
Precipitation and Co-precipitation
Precipitation Gravimetry
In determining nickel by gravimetric analysis, a precipitant of ethanolic dimethylglyoxime is added to a hot nickel salt solution. This is quickly followed by the dropwise addition of dilute ammonia solution until precipitation occurs. A...