Related Experiment Video
Updated: Apr 23, 2026

Study of Experimental Organ Donation Models for Lung Transplantation
Published on: March 15, 2024
[Brain death diagnosis after sedation with propofol or sufentanil. Recommendations for the usage of toxicological
U Walter1, U Brüderlein, M Gloger
1Klinik und Poliklinik für Neurologie, Universitätsmedizin Rostock, Gehlsheimer Str. 20, 18147, Rostock, Deutschland, uwe.walter@med.uni-rostock.de.
Background:
Before the clinical diagnosis of brain death is made, toxicological analyses are often performed for the exclusion of effective serum levels of previously applied sedating drugs. For propofol and sufentanil there are no uniform recommendations for the usage of toxicology test results.
Objectives:
To develop a standard practice in the diagnosis of brain death after therapeutic application of one of these drugs.
Material And Methods:
Based on the current literature and the available analytical assays, an ad hoc working group consisting of specialists in toxicology and intensive care medicine compiled recommendations for the usage of toxicological analytics in the diagnosis of brain death at the Rostock University Hospital.
Results:
For propofol, current analytical assays allow the quantification of serum concentrations of 0.2 μg/ml and lower; the execution of clinical brain death diagnostics is recommended by the ad hoc group only at propofol serum levels lower than 0.4 μg/ml. For sufentanil, the currently prevalent assays set lower determination limits of about 0.2 ng/ml in serum and 0.1 ng/ml in urine, which is above the cautiously adopted lower therapeutic serum concentration of 0.02 ng/ml. Therefore after negative determination of sufentanil (< 0.2 ng/ml) in blood serum, the following alternative procedures are recommended: (1) the execution of clinical brain death diagnostics under administration of naloxone; or (2) at intact renal function the additional negative determination of sufentanil in urine (< 0.1 ng/ml). If an assay allowing the detection of sufentanil at ≤ 0.01 ng/ml is available, brain death diagnostics should be carried out only at a serum level lower than 0.02 ng/ml.
Conclusion:
These recommendations may serve as a proposal for similar standards in other hospitals.
More Related Videos
05:03Brain Death Induction in Mice Using Intra-Arterial Blood Pressure Monitoring and Ventilation via Tracheostomy
Published on: April 17, 2020
10:19Induction of an Isoelectric Brain State to Investigate the Impact of Endogenous Synaptic Activity on Neuronal Excitability In Vivo
Published on: March 31, 2016
Related Concept Videos
Parenteral Anesthetics: Overview
Stages of General Anesthesia
Toxidromes: Clinical Features