Related Experiment Video
Updated: Apr 23, 2026

Thermal Imaging to Study Stress Non-invasively in Unrestrained Birds
Published on: November 6, 2015
Relationship among eye and muzzle temperatures measured using digital infrared thermal imaging and vaginal and rectal
W D George1, R W Godfrey2, R C Ketring1
1Agricultural Experiment Station, University of the Virgin Islands, St. Croix, 00850 VI.
Abstract:
Digital infrared thermal imaging (DITI) using a thermal camera has potential to be a useful tool for the production animal industry. Thermography has been used in both humans and a wide range of animal species to measure body temperature as a method to detect injury or inflammation. The objective of these experiments was to compare the temperature of the eye (EYE) or muzzle (MUZ) measured using DITI to vaginal (VT) and rectal temperature (RT) as measures of core body temperature in hair sheep and beef cattle. In Exp.1 EYE, VT and RT were measured in lactating, multiparous hair sheep ewes (St. Croix White, n = 10, and Dorper × St. Croix White, n = 10) in a non-febrile state 5 times over a 48-h period. Data loggers were used to measure VT and a digital veterinary thermometer was used to measure RT. There was a high correlation (P < 0.001) between VT and RT (r = 0.95), EYE and RT (r = 0.76) and EYE and VT (r = 0.77). In Exp. 2 EYE, MUZ, VT and RT were measured in multiparous, lactating ewes (St. Croix White, n = 2, and Barbados Blackbelly, n = 12) at -12, -1, 0, 1, 2, 3, 4, 6, 12, 24, 36, and 48 h after being administered lipopolysaccharide (LPS; n = 7; 0.2 µg/kg BW, i.v.) or saline (n = 7; 0.5 mL, i.v.). Data loggers were used to measure VT and a digital veterinary thermometer was used to measure RT. When data were combined across treatments (LPS and saline) there was a high correlation (P < 0.001) between VT and RT (r = 0.96), EYE and RT (r = 0.82), MUZ and RT (r = 0.72), and EYE and VT (r = 0.93). In Exp. 3 EYE, MUZ, VT and RT were measured in multiparous, non-lactating, pregnant Senepol cattle (n = 44) between 0900 and 1200 h on a single day. A digital veterinary thermometer was used to measure both VT and RT. There was a high correlation (P < 0.001) between VT and RT (r = 0.78), a moderate correlation (P < 0.001) between VT and EYE (r = 0.52), RT and EYE (r = 0.58) and EYE and MUZ (r = 0.48). There was no correlation (P > 0.10) between RT or VT and MUZ. The findings of these three studies indicate that temperature of the eye, measured using DITI, can be used as an indicator of core body temperature in hair sheep and beef cattle as an alternative to using vaginal or rectal temperature.
Related Concept Videos
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...

