Cristina Mietto1, Riccardo Pinciroli, Annop Piriyapatsom
1From the Department of Anesthesia, Critical Care, and Pain Medicine, Massachusetts General Hospital, Boston, Massachusetts (C.M., R.P., A.P., R.M.K., L. Berra); School of Dentistry, West Virginia University, Morgantown, West Virginia (J.G.T.); Center for Clinical and Translational Metagenomics, Department of Pathology, Brigham and Women's Hospital, Boston, Massachusetts (L. Bry, M.L.D., A.D.B.); Center for System Biology, Massachusetts General Hospital, Boston, Massachusetts (J.T., G.R.W., M.N.); Department of Radiology, Massachusetts General Hospital, Boston, Massachusetts (J.B.A.); and Department of Respiratory Care, Massachusetts General Hospital, Boston, Massachusetts (R.M.K.).
Background:
Tracheal intubation compromises mucus clearance and secretions accumulate inside the tracheal tube (TT). The aim of this study was to evaluate with a novel methodology TT luminal obstruction in critically ill patients.
Methods:
This was a three-phase study: (1) the authors collected 20 TTs at extubation. High-resolution computed tomography (CT) was performed to determine cross-sectional area (CSA) and mucus distribution within the TT; (2) five TTs partially filled with silicone were used to correlate high-resolution CT results and increased airflow resistance; and (3) 20 chest CT scans of intubated patients were reviewed for detection of secretions in ventilated patients' TT.
Results:
Postextubation TTs showed a maximum CSA reduction of (mean±SD) 24.9±3.9% (range 3.3 to 71.2%) after a median intubation of 4.5 (interquartile range 2.5 to 6.5) days. CSA progressively decreased from oral to lung end of used TTs. The luminal volume of air was different between used and new TTs for all internal diameters (P<0.01 for new vs. used TTs for all studied internal diameters). The relationship between pressure drop and increasing airflow rates was nonlinear and depended on minimum CSA available to ventilation. Weak correlation was found between TT occlusion and days of intubation (R²=0.352, P=0.006). With standard clinical chest CT scans, 6 of 20 TTs showed measurable secretions with a CSA reduction of 24.0±3.9%.
Conclusions:
TT luminal narrowing is a common finding and correlates with increased airflow resistance. The authors propose high-resolution CT as a novel technique to visualize and quantify secretions collected within the TT lumen.
Related Concept Videos
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...
Trachea
Anatomical Features:
Location: About half of the trachea is situated in the neck, anterior to the esophagus, and extends from the larynx (at the level of...
Tracheostomy Decannulation
Description of the Procedure
Decannulation refers to the permanent removal of the tracheostomy tube, signaling the resolution of the condition that initially necessitated the tracheostomy. The process requires a well-coordinated interplay between...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...