Multiphase computed tomography for localization of parathyroid disease in patients with primary hyperparathyroidism:
Salem I Noureldine1, Nafi Aygun2, Michael J Walden2
1Division of Head and Neck Endocrine Surgery, Department of Otolaryngology - Head and Neck Surgery, Johns Hopkins University School of Medicine, Baltimore, MD.
Background:
Multiphase computed tomography (CT) involves multiple cervical CT acquisitions to accurately identify hyperfunctional parathyroid glands, thus increasing radiation exposure to the patient. We hypothesized that only 2 cervical acquisitions, instead of the conventional 4, would provide equivalent localization information and halve the radiation exposure.
Methods:
We identified 53 consecutive patients with primary hyperparathyroidism who underwent multiphase CT before parathyroidectomy. All scans were reinterpreted first using 2 phases then using all 4 phases. The accuracies of interpretations were determined with surgical findings serving as the standard of reference.
Results:
Sixty-four hyperfunctional parathyroid glands were resected with a mean weight of 394.3 mg. Two-phase CT lateralized the hyperfunctional glands in 38 patients with a sensitivity, positive predictive value (PPV), and accuracy of 100%, 71.7%, and 71.7%, respectively. Four-phase CT lateralized the hyperfunctional glands in 39 patients with a sensitivity, PPV, and accuracy of 95.1%, 76.5%, and 73.6%, respectively. For quadrant localization, the accuracy of 2-phase and 4-phase CT was 50.9% and 52.8%, respectively.
Conclusion:
Our results suggest that 2-phase and 4-phase CT provide an equivalent diagnostic accuracy in localizing hyperfunctional parathyroid glands. The reduced radiation exposure to the patient may make 2-phase acquisitions a more acceptable alternative for preoperative localization.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
The Parathyroid Glands
Oxyphil cells, whose functions remain elusive, emerge during late puberty, adding a layer of complexity to the parathyroid gland's intricacies. In contrast, principal parathyroid cells undertake a vital role by...
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET