Toward continuous, noninvasive assessment of ventricular function and hemodynamics: wearable ballistocardiography
Abstract:
Ballistocardiography, the measurement of the reaction forces of the body to cardiac ejection of blood, is one of the few techniques available for unobtrusively assessing the mechanical aspects of cardiovascular health outside clinical settings. Recently, multiple experimental studies involving healthy subjects and subjects with various cardiovascular diseases have demonstrated that the ballistocardiogram (BCG) signal can be used to trend cardiac output, contractility, and beat-by-beat ventricular function for arrhythmias. The majority of these studies has been performed with "fixed" BCG instrumentation-such as weighing scales or chairs-rather than wearable measurements. Enabling wearable, and thus continuous, recording of BCG signals would greatly expand the capabilities of the technique; however, BCG signals measured using wearable devices are morphologically dissimilar to measurements from "fixed" instruments, precluding the analysis and interpretation techniques from one domain to be applied to the other. In particular, the time intervals between the electrocardiogram (ECG) and BCG-namely, the R-J interval, a surrogate for measuring contractility changes-are significantly different for the accelerometer compared to a "fixed" BCG measurement. This paper addresses this need for quantitatively normalizing wearable BCG measurement to "fixed" measurements with a systematic experimental approach. With these methods, the same analysis and interpretation techniques developed over the past decade for "fixed" BCG measurement can be successfully translated to wearable measurements.
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Holter Monitor: 24-Hour Monitoring
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...