Left main coronary artery ostial repair with autologous ring-shaped aortic patch for iatrogenic aortic dissection

Cristina Barbero1, Elio Di Rosa, Roger Devotini

  • 1PhD Programme in Applied Technologies to Surgical Science, Division of Cardiac Surgery, Città della Salute e della Scienza Hospital, "Molinette", University of Torino, Torino, Italy; Division of Cardiac Surgery, Città della Salute e della Scienza Hospital, "Molinette", University of Torino, Torino, Italy.

Insights

Iatrogenic left main coronary artery dissection is a rare complication of coronary catheterization. Surgical repair using an aortic wall patch successfully sealed the intimal tear.

Area of Science:

  • Cardiovascular Surgery
  • Interventional Cardiology
  • Vascular Medicine

Background:

  • Coronary catheterization can lead to rare iatrogenic complications.
  • Left main coronary artery (LMCA) dissection and aortic root dissection are significant risks.

Observation:

  • A case of catheter-induced LMCA dissection is presented.
  • The dissection retrogradely progressed into the ascending aorta wall.

Findings:

  • The patient underwent surgical management.
  • Ascending aorta replacement and left coronary ostial repair were performed.
  • An autologous aortic wall ring-shaped patch was used to seal the intimal tear.

Implications:

  • This case highlights a rare but serious complication of coronary catheterization.
  • Surgical techniques involving aortic wall patches can effectively manage such dissections.
  • Emphasizes the importance of prompt surgical intervention for iatrogenic aortic and coronary artery injuries.