Related Experiment Video
Updated: Apr 23, 2026

Dosimetry for Cell Irradiation using Orthovoltage 40-300 kV X-Ray Facilities
Published on: February 20, 2021
Investigation of qualitative and quantitative factors related to radiological exposure to nursing staff during
Hiroshige Mori1, Kichiro Koshida, Osamu Ishigamori
1*Department of Radiology, Hokkaido Social Insurance Hospital, 1-8-3-18 Nakanoshima, Toyohira, Sapporo, Hokkaido 062-8618, Japan; †Department of Quantum Medical Technology, Division of Health Sciences, Graduate School of Medical Science, Kanazawa University, 5-11-80 Kodatsuno, Kanazawa, Ishikawa 920-0942, Japan; ‡School of Health Sciences, College of Medical, Pharmaceutical and Health Science, Kanazawa University, 5-11-80 Kodatsuno, Kanazawa, Ishikawa 920-0942, Japan.
Abstract:
Radiologists or nurses intermittently stay in computed tomography rooms during computed tomography examinations; these actions are defined as “entrance actions.” The qualitative and quantitative factors related to radiological exposure to computed tomography nursing staff were investigated to identify the protective measures against entrance actions. A questionnaire survey was used to investigate the frequency, motives, and causalities of entrance actions. Individual and area monitoring were simultaneously performed. The mean frequency of entrance actions was 1.2 times mo(−1). The primary motive for entrance actions was to dispel anxieties regarding collateral accidents during computed tomography. The nursing staff particularly engaged in close supervision to help the patients cope with contrast media extravasation. The average personal dose equivalent [Hp(10)] to the nurses was 0.21 mSv mo(−1). The ambient dose equivalent [H*(10)] rate was 1.4–3.7 mSv min(−1) at a distance of 1 m from CT gantry centre. Avoidance of entrance actions and collateral accidents would decrease the occupational exposures to nurses.
Related Concept Videos
Radiological Investigation I: X-ray and CT
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Biological Effects of Radiation
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...