Related Experiment Video
Updated: Apr 23, 2026

Dry Powder and Nebulized Aerosol Inhalation of Pharmaceuticals Delivered to Mice Using a Nose-only Exposure System
Published on: April 6, 2017
Performance assessment of a range of commercial jet nebulisers
1Department of Medical Physics, St James's University Hospital, Beckett Street, Leeds, LS9 7TF, UK.
Abstract:
The performance of 14 jet nebulisers was assessed using 4 ml of 0.9% w/v saline and a flow-rate of 10 l/min. Nebulisation time (T), percentage mass of drug released as aerosol (P), rate of emission of aerosol (R) and mass median diameter of aerosol distribution (mmd) were recorded. The Side-Stream (Medic-Aid Ltd.), Sure-Mist (Unimed (UK) Ltd.) and Up-Draft (Hudson Inc.) had the lowest T (561 s, 618 s, 637 s respectively) and the Micro-Cirrus (Intersurgical Ltd.) and Up-Draft II (Hudson Inc.) had the highest T (2466 s, 1659 s respectively). The Micro-Neb III (Lifecare Ltd.), Side-Stream and Respirgard (Marquest Ltd.) produced the highest P (68%, 67%, 66% respectively), the Sure-Mist and Up-draft had the lowest P (46.5%, 39% respectively). The Micro-Cirrus, Up-Draft II (Hudson Inc.) and Venticaire (S and W Vickers) had low R values (0.49, 0.801, 0.905 mg/min respectively), the Side-Stream had the highest R (4.08 mg/min). The Micro-Cirrus had a low mmd (1.04 m). The Pulmo-Neb (DeVilbiss Ltd.), Unineb (Unimed (UK) Ltd.) and Up-Draft had relatively high mmd (4.97 μm, 4.34 μm, 4.24 μm).
Related Concept Videos
Inhaled Medications
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Pulmonary Function Tests
Pulmonary Function Tests are crucial diagnostic tools for assessing respiratory function, particularly in patients with chronic respiratory disorders. They comprehensively evaluate lung volumes, ventilatory function, breathing mechanics, diffusion, and gas exchange. These tests help diagnose pulmonary diseases and play a significant role in monitoring disease progression, evaluating disability, and assessing response to therapy.
PFTs involve using a spirometer, a...
Suctioning the Nasopharyngeal Airway
Equipment Required
Administering Oxygen by Nasal Cannula
Nasal Cannulas
A nasal cannula is a lightweight tube split into two prongs placed in the nostrils,...
Assessment of Respiration