A Modified Sonographic Algorithm for Image Acquisition in Life-Threatening Emergencies in the Critically Ill Newborn
Published on: April 7, 2023
A bedside clinical and ultrasound-based approach to hemodynamic instability - Part II: bedside ultrasound in
Annette Vegas1, André Denault, Colin Royse
1Department of Anesthesiology, Toronto General Hospital, University of Toronto, Toronto, ON, Canada.
Unlabelled:
Shock is defined as a situation where oxygen transport and delivery is inadequate to meet oxygen demand. The patient in shock is evaluated through medical history, physical examination, and careful observation of the hemodynamic and respiratory monitors. The patient is initially managed with basic resuscitation measures, however bedside ultrasound should be performed if hemodynamic instability persists. We propose to use ultrasound of the inferior vena cava (IVC), and the concept of venous return, as the initial step in order to identify the mechanism of shock. Doppler examination of the hepatic venous flow can also be added. Further ultrasound examination of the patient's heart, thorax, and abdomen can then be performed in order to determine the etiology of shock. In patients with reduced mean systemic venous pressure, an examination of the patient's thoracic and abdominal cavities to detect free fluid, pneumonia, or empyema can be considered. In patients with increased right atrial pressure, transthoracic echocardiography will allow identification of left or right ventricular dysfunction. Finally, in the presence of increased resistance to venous return, thoracic examination for pneumothorax or cardiac tamponade and abdominal examination for signs of abdominal compartment syndrome or IVC occlusion can be considered. Subsequent treatment can then be tailored to the etiology of shock. Elements of bedside ultrasound examination are currently taught in many anesthesia training programs.
Purpose:
To develop an approach to the patient in shock that incorporates bedside ultrasound examination.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Blood Pressure Imbalances and Circulatory Shock
Blood Pressure: Hypertension and Hypotension
Normal blood pressure is 120/80 mm Hg. Elevated blood pressure is 120-129/under 80 mm Hg. Hypertension, warranting treatment at 130/80 mm Hg, is often asymptomatic and can lead to severe cardiovascular events, aneurysms, peripheral arterial disease, chronic renal disease, or cardiac...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...