Related Experiment Video
Updated: Apr 23, 2026

Synthesis, Characterization, and Application of Superparamagnetic Iron Oxide Nanoprobes for Extrapulmonary Tuberculosis Detection
Published on: February 16, 2020
Optimization of ultrasmall superparamagnetic iron oxide (P904)-enhanced magnetic resonance imaging of lymph nodes:
Roh-Eul Yoo1, Hye Rim Cho2, Seung Hong Choi3
1Department of Radiology, Seoul National University College of Medicine, Seoul, Republic of Korea.
Background:
P904 is a novel ultra-small superparamagnetic iron oxide (USPIO) contrast agent. This study was conducted to investigate the optimal dose of P904 for magnetic resonance imaging (MRI) of lymph nodes.
Materials And Methods:
T2*-weighted 3T MRI was performed in 14 normal mice before and 24 h after P904 injection at varying doses. Normalized signal intensity (nSI), signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and contrast ratio (CR) were calculated to determine the optimal dose. MRI of the metastatic lymph node models (n=5) was acquired using the optimal dose and correlated with pathological results to calculate sensitivity and specificity. The mean SI ratio between pre- and postcontrast MRI was also calculated for each lymph node.
Results:
The mean nSI and SNR values on postcontrast images were significantly lower at 300 μmol Fe/kg than at 75 μmol Fe/kg (p<0.001). The mean CNR and CR values were significantly higher at 300 μmol Fe/kg than at the other two doses (p<0.05). At the optimal dose of 300 μmol Fe/kg, the mean SI ratio of benign lymph nodes was significantly lower than that of metastatic lymph nodes (p<0.001). The Az (areas under the receiver operating characteristic curves) value for diagnosing lymph node metastasis at the optimal dose was 0.97.
Conclusion:
The optimal dose for P904-enhanced MRI of the lymph nodes was 300 μmol Fe/kg, which could be used for the diagnosis of lymph node metastasis.