Related Experiment Video
Updated: Apr 23, 2026

Automated Hydrophobic Interaction Chromatography Column Selection for Use in Protein Purification
Published on: September 21, 2011
Facile preparation of organic-inorganic hybrid polymeric ionic liquid monolithic column with a one-pot process for
Cuicui Liu1, Qiliang Deng, Guozhen Fang
1Key Laboratory of Food Nutrition and Safety, Ministry of Education, Tianjin Key Laboratory of Food Nutrition and Safety, Tianjin University of Science and Technology, Tianjin, 300457, China.
Abstract:
An organic-inorganic hybrid monolithic column based on 1-vinyl-3-dodecylimidazolium bromide (VC12Im(+)Br(-)) has been prepared in a single step by combining radical copolymerization with a non-hydrolytic sol-gel (NHSG) process. The NHSG process was significantly shortened to 6 h by using formic acid as catalyst. For comparison, we also prepared polymeric ionic liquid (PIL) monolithic columns by hydrolytic sol-gel and organic polymeric process, respectively. The resulting monolithic columns were characterized by Fourier transform infrared spectra, scanning electron microscopy, and Brunauer-Emmett-Teller. Under the capillary electrochromatography mode, these columns were applied to separate alkylbenzenes, anilines, and proteins, respectively. The results indicated that the NHSG-based hybrid PIL monolithic column exhibited the highest column efficiency among the three types of columns; organic solvent, commonly required by the traditional columns to achieve satisfactory separation efficiency for proteins, was absent in the NHSG-based hybrid PIL monolithic column because of the biocompatibility of the VC12Im(+)Br(-), which was beneficial to analysis of protein containing samples. In order to demonstrate its application potential, the developed NHSG-based hybrid PIL monolithic column was also employed to separate egg white sample.
More Related Videos
10:27Preparation of Highly Porous Coordination Polymer Coatings on Macroporous Polymer Monoliths for Enhanced Enrichment of Phosphopeptides
Published on: July 14, 2015
10:41Ion Exchange Chromatography IEX Coupled to Multi-angle Light Scattering MALS for Protein Separation and Characterization
Published on: April 5, 2019
Related Concept Videos
Ion-Exchange Chromatography
Types Of Column Chromatography
Gel Filtration Chromatography
When the...
Principles Of Column Chromatography
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Ion Exchange
High-Performance Liquid Chromatography: Elution Process