Related Experiment Video
Updated: Apr 23, 2026

Four-Dimensional CT Analysis Using Sequential 3D-3D Registration
Published on: November 23, 2019
Cross-relaxation imaging of human patellar cartilage in vivo at 3.0T
N Sritanyaratana1, A Samsonov2, P Mossahebi1
1Department of Biomedical Engineering, University of Wisconsin School of Medicine and Public Health, Madison, WI 53792-3252, USA.
Objective:
To compare quantitative magnetization transfer (qMT) parameters of patellar cartilage measured using cross-relaxation imaging (CRI) in asymptomatic volunteers and patients with osteoarthritis.
Design:
The study was performed with Institutional Review Board approval and with all subjects signing informed consent. CRI of the knee joint was performed at 3.0T on 20 asymptomatic volunteers and 11 patients with osteoarthritis. The fraction of macromolecular bound protons (f), the exchange rate constant between macromolecular bound protons and free water protons (k), and the T2 relaxation time of macromolecular bound protons (T2(B)) of patellar cartilage were measured. Mann-Whitney-Wilcoxon rank-sum tests were used to compare qMT parameters between asymptomatic volunteers and patients with osteoarthritis.
Results:
Average f, k, and T2(B) of patellar cartilage was 12.46%, 7.22 s(-1), and 6.49 μs respectively for asymptomatic volunteers and 12.80%, 6.13 s(-1), and 6.80 μs respectively for patients with osteoarthritis. There were statistically significant differences between groups of subjects for k (P < 0.01) and T2(B) (P < 0.0001) but not f (P = 0.38) of patellar cartilage.
Conclusion:
Patients with osteoarthritis had significantly lower k and significantly higher T2(B) of patellar cartilage than asymptomatic volunteers which suggests that qMT parameters can detect changes in the macromolecular matrix of degenerative cartilage.
More Related Videos
07:09In situ Compressive Loading and Correlative Noninvasive Imaging of the Bone-periodontal Ligament-tooth Fibrous Joint
Published on: March 7, 2014
06:27Author Spotlight: Investigating Early Events and Long-Term Effects of ACL Injuries for Osteoarthritis Progression
Published on: September 29, 2023
Related Concept Videos
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies for Cardiovascular System IV: CMRI
Magnetic Resonance Imaging
Imaging Studies IV: Magnetic Resonance Imaging
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...