Related Experiment Video
Updated: Apr 23, 2026

ELIME Enzyme Linked Immuno Magnetic Electrochemical Method for Mycotoxin Detection
Published on: October 23, 2009
Electrochemical magnetoimmunosensing platform for determination of the milk allergen β-lactoglobulin
V Ruiz-Valdepeñas Montiel1, S Campuzano1, F Conzuelo1
1Departamento de Química Analítica, Facultad de CC. Químicas, Universidad Complutense de Madrid, E-28040 Madrid, Spain.
Abstract:
A very sensitive magnetoimmunosensor for the determination of β-lactoglobulin (β-LG) is reported in this work. A sandwich configuration involving covalent immobilization of the capture antibody (antiβ-LG) onto activated carboxylic-modified magnetic beads (HOOC-MBs) and incubation of the modified MBs with a horseradish peroxidase labeled antibody (HRP-antiβ-LG), is used. The resulting modified MBs are captured by a magnet placed under the surface of a disposable carbon screen-printed electrode (SPCE) and the amperometric responses are measured at -0.20 V (vs. Ag pseudo-reference electrode), upon addition of hydroquinone (HQ) as electron transfer mediator and H2O2 as the enzyme substrate. The β-LG magnetoimmunosensor exhibited a wide range of linearity (2.8-100 ng mL(-1)) and a low detection limit of 0.8 ng mL(-1) (20 pg in 25 μL sample). The magnetoimmunosensing platform was successfully applied for the detection of β-LG in different types of milk without any matrix effect after just a sample dilution. The results correlated properly with those provided by a commercial ELISA method offering a truthful analytical screening tool. These features make the developed methodology a promising alternative in the development of user-friendly devices for on-site determination of β-LG in dairy products.