Related Experiment Video
Updated: Apr 23, 2026

Direct Pressure Monitoring Accurately Predicts Pulmonary Vein Occlusion During Cryoballoon Ablation
Published on: February 26, 2013
Pulmonary vein isolation as index procedure for persistent atrial fibrillation: One-year clinical outcome after
Giuseppe Ciconte1, Luca Ottaviano2, Carlo de Asmundis1
1Heart Rhythm Management Centre, UZ Brussel-VUB, Brussels, Belgium.
Background:
No data are available about the clinical outcome of pulmonary vein isolation (PVI) as an index procedure for persistent atrial fibrillation (PersAF) ablation using the second-generation cryoballoon (CB-Adv).
Objective:
The purpose of this study was to assess the 1-year efficacy of PVI as an index procedure for PersAF ablation using the novel CB-Adv.
Methods:
Sixty-three consecutive patients (45 male [71.4%], mean age 62.7 ± 9.7 years) with drug-refractory PersAF undergoing PVI using the novel CB-Adv were enrolled. Follow-up was based on outpatient clinic visits including Holter ECGs. Recurrence of atrial tachyarrhythmias (ATas) was defined as a symptomatic or documented episode >30 seconds.
Results:
A total of 247 PVs were identified and successfully isolated with a mean of 1.7 ± 0.4 freezes. Mean procedural and fluoroscopy times were 87.1 ± 38.2 minutes and 14.9 ± 6.1 minutes, respectively. Among 26 of 63 patients (41.3%) presenting with AF at the beginning of the procedure, 7 of 26 (26.9%) converted to sinus rhythm during ablation. Phrenic nerve palsy occurred in 4 of 63 patients (6.3%). At 1-year follow-up, after a 3-month blanking period (BP), 38 of 63 patients (60.3%) were in sinus rhythm. Because of ATa recurrences, 9 patients underwent a second procedure with radiofrequency ablation showing a pulmonary vein reconnection in 4 right-sided PVs (44.4%) and 3 left-sided PVs (33.3%). Multivariate analysis demonstrated that PersAF duration (P = .01) and relapses during BP (P = .04) were independent predictors of AT recurrences.
Conclusion:
At 1-year follow-up, freedom from ATas following PersAF ablation with the novel CB-Adv is 60%. Phrenic nerve palsy is the most common complication. PersAF duration and relapses during the BP appear to be significant predictors of arrhythmic recurrences.
More Related Videos
08:00Reduction of Iatrogenic Atrial Septal Defects with an Anterior and Inferior Transseptal Puncture Site when Operating the Cryoballoon Ablation Catheter
Published on: June 15, 2015
06:48Three-Dimensional Echocardiographic Method for the Visualization and Assessment of Specific Parameters of the Pulmonary Veins
Published on: October 28, 2020