A nonvoxel-based dose convolution/superposition algorithm optimized for scalable GPU architectures

J Neylon1, K Sheng1, V Yu1

  • 1Department of Radiation Oncology, University of California Los Angeles, 200 Medical Plaza, #B265, Los Angeles, California 90095.

Medical Physics
|October 6, 2014
PubMed
Abstract

Related Concept Videos

Convolution: Math, Graphics, and Discrete Signals01:24

Convolution: Math, Graphics, and Discrete Signals

In any LTI (Linear Time-Invariant) system, the convolution of two signals is denoted using a convolution operator, assuming all initial conditions are zero. The convolution integral can be divided into two parts: the zero-input or natural response and the zero-state or forced response, with t0 indicating the initial time.
To simplify the convolution integral, it is assumed that both the input signal and impulse response are zero for negative time values. The graphical convolution process...
1.3K
Convolution Properties II01:17

Convolution Properties II

The important convolution properties include width, area, differentiation, and integration properties.
The width property indicates that if the durations of input signals are T1 and T2, then the width of the output response equals the sum of both durations, irrespective of the shapes of the two functions. For instance, convolving two rectangular pulses with durations of 2 seconds and 1 second results in a function with a width of 3 seconds.
The area property asserts that the area under the...
750
Convolution Properties I01:20

Convolution Properties I

Convolution computations can be simplified by utilizing their inherent properties.
The commutative property reveals that the input and the impulse response of an LTI (Linear Time-Invariant) system can be interchanged without affecting the output:
772
Computed Tomography01:10

Computed Tomography

Tomography refers to imaging by sections. Computed tomography (CT) is a non-invasive imaging technique that uses computers to analyze several cross-sectional X-rays to reveal minute details about structures in the body.
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
7.5K
Deconvolution01:20

Deconvolution

Deconvolution, also known as inverse filtering, is the process of extracting the impulse response from known input and output signals. This technique is vital in scenarios where the system's characteristics are unknown, and they must be inferred from the observable signals.
Deconvolution involves several mathematical techniques to derive the impulse response. One common approach is polynomial division. In this method, the input and output sequences are treated as coefficients of...
763
Upsampling01:22

Upsampling

Managing signal sampling rates is essential in digital signal processing to maintain signal integrity. A decimated signal, characterized by a reduced frequency range due to its lower sampling rate, can be upsampled by inserting zeros between each sample. This upsampling process expands the original spectrum and introduces repeated spectral replicas at intervals dictated by the new Nyquist frequency. To refine this zero-inserted sequence, it is passed through a lowpass filter with a cutoff...
743