Related Experiment Video
Updated: Apr 23, 2026

An Alternative to the Traditional Cold Pressor Test: The Cold Pressor Arm Wrap
Published on: January 16, 2014
[Evaluation of active equipment protecting distal parts of hands and feet against cold]
Abstract:
Experimental studies covered thermoregulatory reactions of feet and hands, when using equipment protecting distal parts of hands and feet and using "active" heating (electric heating and thermochemical heater). Findings are that "active" heaters with output range 4-8 watt, as electrically heated inserts in gauntlets and welts, at air temperatures of -5 to -10 degrees C maintained average skin temperature of hand at 17-20 degrees C; using "active" heaters with output of 12 watt increased heat insulation of gauntlets and shoes up to 0.609-0.609 degrees C x m2/watt--that enables to conduct averagely hard work at cold climate up to 2 hours in all climate regions--IA (special), IB (climate zone IV), II (climate zone III) and III (climate zone II). Using 2 thermochemical heaters in gauntlets prevented local cooling, and heat insulation of the gauntlets therefore increased 1.6 times--that enables to widen temperature range of safe usage of equipment protecting hands against cold up to climate region II (climate zone III) during continuous physical work of average hardiness in cold climate up to 2 hours.
Related Concept Videos
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Decreased Body Temperature
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Personal Protective Equipment
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Frost Action on Concrete
This freeze-thaw cycle primarily causes surface scaling, where...

