Related Experiment Video
Updated: Apr 23, 2026

Combining Volumetric Capnography And Barometric Plethysmography To Measure The Lung Structure-function Relationship
Published on: January 8, 2019
Volumetric capnography for the evaluation of chronic airways diseases
Liliani Veronez1, Monica Corso Pereira2, Silvia Maria Doria da Silva2
1Department of Physical Therapy, University of Votuporanga (Educational Foundation of Votuporanga), Votuporanga, Brazil.
Background:
Obstructive lung diseases of different etiologies present with progressive peripheral airway involvement. The peripheral airways, known as the silent lung zone, are not adequately evaluated with conventional function tests. The principle of gas washout has been used to detect pulmonary ventilation inhomogeneity and to estimate the location of the underlying disease process. Volumetric capnography (VC) analyzes the pattern of CO2 elimination as a function of expired volume.
Objective:
To measure normalized phase 3 slopes with VC in patients with non-cystic fibrosis bronchiectasis (NCB) and in bronchitic patients with chronic obstructive pulmonary disease (COPD) in order to compare the slopes obtained for the groups.
Methods:
NCB and severe COPD were enrolled sequentially from an outpatient clinic (Hospital of the State University of Campinas). A control group was established for the NCB group, paired by sex and age. All subjects performed spirometry, VC, and the 6-Minute Walk Test (6MWT). Two comparisons were made: NCB group versus its control group, and NCB group versus COPD group. The project was approved by the ethical committee of the institution. Statistical tests used were Wilcoxon or Student's t-test; P<0.05 was considered to be a statistically significant difference.
Results:
Concerning the NCB group (N=20) versus the control group (N=20), significant differences were found in body mass index and in several functional variables (spirometric, VC, 6MWT) with worse results observed in the NCB group. In the comparison between the COPD group (N=20) versus the NCB group, although patients with COPD had worse spirometric and 6MWT values, the capnographic variables mean phase 2 slope (Slp2), mean phase 3 slope normalized by the mean expiratory volume, or mean phase 3 slope normalized by the end-tidal CO2 concentration were similar.
Conclusion:
These findings may indicate that the gas elimination curves are not sensitive enough to monitor the severity of structural abnormalities. The role of normalized phase 3 slope may be worth exploring as a more sensitive index of small airway disease, even though it may not be equally sensitive in discriminating the severity of the alterations.
More Related Videos
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Respiratory Volumes
Tidal Volume (TV) Tidal volume (TV) is the air inhaled or exhaled in a...
Chronic Obstructive Pulmonary Disease-IV: Assessement and Diagnostic Studies
Medical History
Respiratory Volumes and Capacities I
Respiratory Volumes and Capacities
Acute Respiratory Failure-III