In Vitro Application of a Wireless Sensor in Flexion-Extension Gap Balance of Unicompartmental Knee Arthroplasty
Published on: May 5, 2023
Biomechanical validation of medial pie-crusting for soft-tissue balancing in knee arthroplasty
William M Mihalko1, Erik L Woodard1, Casey T Hebert1
1University of Tennessee-Campbell Clinic Department of Orthopaedic Surgery & Biomedical, Engineering, Memphis, Tennessee.
Abstract:
Balancing a varus knee is traditionally accomplished by releasing the medial soft-tissue sleeve off the tibia. Recently, "pie-crusting" (PC) medial structures has been described. In a biomechanical cadaver study we compared PC to traditional release (TR) to determine their effects on flexion and extension gaps. PC was done in five specimens along the anterior half of the medial soft-tissue sleeve and five along the posterior half, followed by a traditional release. In 90° flexion, valgus laxity after TR was significantly greater than after PC alone. PC of the anterior or posterior aspect of the medial soft-tissue sleeve can effect changes more in flexion than in extension, respectively. Complete TR did not provide more gap opening than PC in extension, but produced more effect in flexion.