Related Experiment Video
Updated: Apr 22, 2026

Midface Hypoplasia and Cranial Base Morphology in Syndromic Craniosynostosis: A Comparative Analysis Study Using a Predictive Regression Model
Published on: November 4, 2025
A computed tomography morphometric study of occipital bone and C2 pedicle anatomy for occipital-cervical fusion
Nicolas K K King1, Tiruchelvarayan Rajendra2, Ivan Ng1
1Department of Neurosurgery, National Neuroscience Institute, Singapore General Hospital, Outram Road, Singapore 169608.
Background:
Occipital-cervical fusion (OCF) has been used to treat instability of the occipito-cervical junction and to provide biomechanical stability after decompressive surgery. The specific areas that require detailed morphologic knowledge to prevent technical failures are the thickness of the occipital bone and diameter of the C2 pedicle, as the occipital midline bone and the C2 pedicle have structurally the strongest bone to provide the biomechanical purchase for cranio-cervical instrumentation. The aim of this study was to perform a quantitative morphometric analysis using computed tomography (CT) to determine the variability of the occipital bone thickness and C2 pedicle thickness to optimize screw placement for OCF in a South East Asian population.
Methods:
Thirty patients undergoing cranio-cervical junction instrumentation during the period 2008-2010 were included. The thickness of the occipital bone and the length and diameter of the C2 pedicle were measured based on CT.
Results:
The thickest point on the occipital bone was in the midline with a maximum thickness below the external occipital protuberance of 16.2 mm (±3.0 mm), which was thicker than in the Western population. The average C2 pedicle diameter was 5.3 mm (±2.0 mm). This was smaller than Western population pedicle diameters. The average length of the both pedicles to the midpoint of the C2 vertebral body was 23.5 mm (±3.3 mm on the left and ±2.3 mm on the right).
Conclusions:
The results of this first study in the South East Asian population should help guide and improve the safety in occipito-cervical region instrumentation. Thus reducing the risk of technical failures and neuro-vascular injury.
More Related Videos
10:23Author Spotlight: Three-Dimensional Cephalometric Landmark Annotation Demonstration on Human Cone Beam Computed Tomography Scans
Published on: September 8, 2023
02:42Analysis of Craniomaxillofacial Malformations in Mice Using Three-dimensional Microcomputed Tomography
Published on: January 17, 2025
Related Concept Videos
Cranial Bones: Superior and Posterior View
The frontal bone is the single bone that forms the forehead. At its anterior midline, between the eyebrows, there is a slight depression called the glabella. The frontal bone also forms the supraorbital margin of the orbit. Near the middle of this margin is the supraorbital foramen, the opening that provides passage for a sensory nerve to the forehead. The frontal bone is thickened just above each supraorbital margin,...
Sutures of the Skull
Sutures are immobile joints between adjacent bones of the skull. The narrow gap between the bones is filled with dense, fibrous connective tissue that unites the bones. The long sutures located between the skull bones are not straight but instead follow irregular, tightly twisting paths. These twisting lines tightly...
Cranial Bones: Lateral View
The temporal bone forms the lower lateral side of the skull. The temporal bone is subdivided into several regions. The flattened upper portion is the squamous portion of the temporal bone. Below this area and projecting anteriorly is the zygomatic process of the temporal bone, which forms the posterior portion of the zygomatic arch. Posteriorly is the mastoid portion of the temporal bone. Projecting...
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...