Related Experiment Video
Updated: Apr 22, 2026

Continuous Venous-Arterial Doppler Ultrasound During a Preload Challenge
Published on: January 20, 2023
Transcranial Doppler Sonography: Atypical Dicrotic Pulse Waveforms in a Man with HIV Infection and Severe
Sureerat Suwatcharangkoon1,2, Dana B Meads1, Charles H Tegeler1
1Department of Neurology, Wake Forest University Baptist Medical Center, Winston-Salem.
Abstract:
A 27-year-old human immunodeficiency virus--positive man presented with abdominal pain. Computed tomography of the abdomen revealed large right pleural effusion, pericardial effusion and marked ascites with diffuse intra- and extraperitoneal lymphadenopathy. Echocardiography showed severely reduced left ventricular systolic function. After drainage of pleural and pericardial fluid, the patient developed severe hypotension and hypoxic respiratory failure. Extra- and intracranial neurovascular sonography demonstrated low carotid artery flow volume and dicrotic pulse waveforms in all vessels insonated bilaterally. This case report demonstrates an atypical dicrotic waveform pattern of transcranial Doppler in advanced ventricular dysfunction with shock.
More Related Videos
11:50High-frequency High-resolution Echocardiography: First Evidence on Non-invasive Repeated Measure of Myocardial Strain, Contractility, and Mitral Regurgitation in the Ischemia-reperfused Murine Heart
Published on: July 9, 2010
08:19Transthoracic Echocardiography to Assess Post-Resuscitation Left Ventricular Dysfunction After Acute Myocardial Infarction and Cardiac Arrest in Pigs
Published on: July 12, 2022
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Rheumatic Heart Disease II: Clinical Manifestations and Diagnostic Studies
Cardiovascular System Abnormal Findings I: Inspection and Palpation
Abnormal findings observed during an inspection
Cardiovascular System Abnormal Findings II: Auscultation
Abnormal Heart Sounds
Gallops:
Cardiomyopathy II: Dilated Cardiomyopathy
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...