Related Experiment Video For cyst formation
Updated: Aug 15, 2026

MR Molecular Imaging of Prostate Cancer with a Small Molecular CLT1 Peptide Targeted Contrast Agent
Published on: September 3, 2013
Prostate cancer with cyst formation detected by whole body positron emission tomography/computed tomography: A case
Hakushi Kim1, Sunao Shoji1, Tetsuro Tomonaga1
1Department of Urology, Tokai University Hachioji Hospital, Hachioji, Tokyo 192-0032, Japan.
Abstract:
The present study reports a case of prostate adenocarcinoma with cyst formation. A 72-year-old male diagnosed with multiple lung metastases at a local clinic was referred to Tokai University Hachioji Hospital (Tokyo, Japan) for detection of a primary lesion. Whole body positron emission tomography/computed tomography showed strong accumulation of [18F]-fluoro-deoxy-2-glucose (FDG) in the small pelvis, and pelvic magnetic resonance imaging revealed a 60×40-mm cystic lesion, with an irregular thickened wall, behind the prostate. The serum prostate-specific antigen (PSA) level was elevated to 211.99 ng/ml, therefore, the patient underwent a transperineal prostate needle biopsy, and was diagnosed with prostate adenocarcinoma with cyst formation. Androgen deprivation therapy was administered for 8 months following the diagnosis of prostate cancer; consequently, the cyst reduced in size and the serum PSA level decreased to 0.14 ng/ml. To the best of our knowledge, this is the first report of a malignant prostatic cyst detected by FDG-positron emission tomography/computed tomography.
More Related Videos
09:49A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy PRRT: 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
06:08A Cognitive Fusion-guided Prostate Biopsy Using Multiparametric Magnetic Resonance Imaging and Transrectal Ultrasound
Published on: March 21, 2025
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Imaging Studies III: Computed Tomography