Related Experiment Video
Updated: Apr 22, 2026

A Rodent Model of The Ross Operation: Syngeneic Pulmonary Artery Graft Implantation in A Systemic Position
Published on: April 1, 2022
Pulmonary homograft endocarditis and aortic autograft failure after Ross procedure: a double stentless bioprosthesis
Abstract:
The case is reported of a 38-year-old male patient with pulmonary homograft acute infective endocarditis and aortic root dilation that occurred 13 years after a Ross procedure for bicuspid aortic valve regurgitation. Aortic and pulmonary root replacements were performed, using a Freestyle stentless aortic root bioprosthesis in both cases, with excellent hemodynamics on postoperative echocardiography. In addition, preoperative systemic septic embolization had occurred despite an absence of left-sided endocarditis, presumably due to an intrapulmonary shunt. This case report demonstrates the feasibility of a double stentless bioprosthesis approach, and stresses the need to remain vigilant for septic embolization even in isolated right-sided endocarditis.