Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Extending the age cutoff: Outcomes of the Ross procedure in patients older than 60 years. A two-center retrospective study from the Canadian Ross Registry.

The Journal of thoracic and cardiovascular surgery·2026
Same author

Contemporary Outcomes of the Ross Procedure in Adults: Implications for Current Clinical Practice.

Journal of the American College of Cardiology·2026
Same author

Medium-term outcomes of aortic valve-sparing procedure in trileaflet valve: Longitudinal analysis from the Heart Valve Society Registry.

JTCVS structural and endovascular·2026
Same author

How I do it: Bicuspid valve-sparing aortic root replacement using a remodeling procedure with extra-aortic ring annuloplasty.

JTCVS structural and endovascular·2026
Same author

Contemporary surgical outcomes and repair rates in degenerative mitral regurgitation: Real-world insights from the international MITRACURE registry.

The Journal of thoracic and cardiovascular surgery·2026
Same author

5-Year Outcomes of the Dissected Aorta Repair Through Stent (DARTS) Implantation Trial.

The Annals of thoracic surgery·2026
Same journal

Totally endoscopic three-dimensional tricuspid valve repair in an adult with Ebstein's anomaly.

Multimedia manual of cardiothoracic surgery : MMCTS·2026
Same journal

Root replacement after transcatheter aortic valve replacement in homograft explant.

Multimedia manual of cardiothoracic surgery : MMCTS·2026
Same journal

Tetralogy of Fallot with single coronary artery and pulmonary thromboembolism in a 7-year-old child: surgical management and technical considerations.

Multimedia manual of cardiothoracic surgery : MMCTS·2026
Same journal

Percutaneous dilation tracheostomy guided by rigid bronchoscopy.

Multimedia manual of cardiothoracic surgery : MMCTS·2026
Same journal

Non-intubated robotic-assisted apicodorsal left lung segmentectomy (S¹⁺²b-c) for a non-small cell lung carcinoma.

Multimedia manual of cardiothoracic surgery : MMCTS·2026
Same journal

Extent II open thoracoabdominal aortic aneurysm repair in severe cachexia.

Multimedia manual of cardiothoracic surgery : MMCTS·2026
See all related articles

Related Experiment Video

Updated: Apr 22, 2026

Standardized Technique of Aortic Valve Re-implantation for Valve-sparing Aortic Root Replacement
14:14

Standardized Technique of Aortic Valve Re-implantation for Valve-sparing Aortic Root Replacement

Published on: December 11, 2017

13.3K

The Ross procedure: total root technique.

Jessica Forcillo1, Mustafa Cikirikcioglu2, Nancy Poirier1

  • 1Department of Cardiac Surgery, Montreal Heart Institute, Université de Montréal, Quebec, Canada.

Multimedia Manual of Cardiothoracic Surgery : MMCTS
|October 10, 2014
PubMed
Summary
This summary is machine-generated.

This study details a novel Ross procedure technique using a total root method without foreign materials for autograft support. The approach prioritizes surgical anatomy to enhance aortic root dynamics and ensure lasting autograft stability.

Keywords:
Pulmonary autograftRoss procedureSurgical technique

More Related Videos

Full-root Aortic Valve Replacement by Stentless Aortic Xenografts in Patients with Small Aortic Roots
12:17

Full-root Aortic Valve Replacement by Stentless Aortic Xenografts in Patients with Small Aortic Roots

Published on: May 21, 2017

10.5K
Treatment of Ankle Osteoarthritis with Total Ankle Replacement Through a Lateral Transfibular Approach
09:01

Treatment of Ankle Osteoarthritis with Total Ankle Replacement Through a Lateral Transfibular Approach

Published on: January 24, 2018

12.0K

Related Experiment Videos

Last Updated: Apr 22, 2026

Standardized Technique of Aortic Valve Re-implantation for Valve-sparing Aortic Root Replacement
14:14

Standardized Technique of Aortic Valve Re-implantation for Valve-sparing Aortic Root Replacement

Published on: December 11, 2017

13.3K
Full-root Aortic Valve Replacement by Stentless Aortic Xenografts in Patients with Small Aortic Roots
12:17

Full-root Aortic Valve Replacement by Stentless Aortic Xenografts in Patients with Small Aortic Roots

Published on: May 21, 2017

10.5K
Treatment of Ankle Osteoarthritis with Total Ankle Replacement Through a Lateral Transfibular Approach
09:01

Treatment of Ankle Osteoarthritis with Total Ankle Replacement Through a Lateral Transfibular Approach

Published on: January 24, 2018

12.0K

Area of Science:

  • Cardiovascular Surgery
  • Thoracic Surgery
  • Surgical Innovation

Background:

  • The Ross procedure is a complex cardiac surgery involving aortic valve replacement.
  • Autograft support and aortic root dynamics are critical for long-term success.
  • Current techniques may involve foreign materials, raising concerns about durability.

Purpose of the Study:

  • To present a novel technique for the Ross procedure.
  • To achieve autograft support without any foreign material.
  • To optimize aortic root dynamics and long-term autograft stability.

Main Methods:

  • Description of a total root technique for the Ross procedure.
  • Emphasis on surgical principles derived from aortic and pulmonary root anatomy.
  • Focus on techniques to enhance autograft root stability and function.

Main Results:

  • Successful application of a foreign material-free total root technique.
  • Demonstrated optimization of aortic root dynamics.
  • Evidence of long-term stability of the autograft root.

Conclusions:

  • The described total root technique offers a viable, foreign material-free alternative for the Ross procedure.
  • Adherence to anatomical principles is key to achieving optimal aortic root dynamics.
  • This method ensures enhanced long-term stability of the autograft root, improving patient outcomes.