Related Experiment Video
Updated: Apr 22, 2026

Author Spotlight: Advancing Rapid Detection of Respiratory Pathogens Using Microfluidic Chip
Published on: March 29, 2024
Molecular panel for detection of sepsis-related microorganisms
Leslie Ecker Ferreira1, Karilene Dalposso2, Bruna Barbosa Hackbarth2
1Programa de Pós-graduação em Saúde e Meio Ambiente, Universidade da Região de Joinville, Joinville, SC, Brasil.
Introduction:
Sepsis is a systemic inflammatory response related to high mortality rates in the hospital environment. Delayed etiological diagnosis and inadequate antimicrobial therapy are associated with treatment failures. Molecular tests based on polymerase chain reaction are regarded as faster and more accurate procedures than culture techniques for microbial identification, providing a higher rate of therapeutic success.
Objective:
To develop a panel of primers for DNA fragments of sepsis-related microorganisms.
Methods:
Primers for amplification of Enterobacter spp., Escherichia coli, Pseudomonas aeruginosa, Staphylococcus aureus and Candida spp. were designed and tested for sensitivity and specificity on the basis of their respective standard strains.
Results:
The intended specificity was obtained for P. aeruginosa, S. aureus and Candida spp primers. Sensitivity tests showed a threshold for detection from 5 ng to 500 fg in blood samples contaminated with microbial DNA.
Conclusions:
The molecular panel presented offers the advantage of a flexible 'open' system when compared to other multiplex detection methods.
More Related Videos
Related Concept Videos
Automated Microbial Diagnostics
Microbial Biosensors