Coronary computed tomographic angiography in coronary artery bypass grafts: comparison between low-concentration
1From the *Department of Radiology, Beijing Anzhen Hospital, Capital Medical University, Beijing, China; and †Discipline of Medical Imaging, Department of Imaging and Applied Physics, Curtin University, Perth, Western Australia, Australia.
Objective:
The aim of this study was to evaluate the feasibility of low-concentration iso-osmolar Iodixanol 270 compared with Iohexol 350 in patients with coronary artery bypass grafts (CABGs) undergoing coronary computed tomographic angiography (CCTA).
Methods:
A total of 80 consecutive patients undergoing CABG follow-up with the use of CCTA were prospectively enrolled, with 40 patients assigned to Iodixanol 270 and 40 patients assigned to Iohexol 350. In both groups, the contrast medium was injected at an injection rate of 4.5 mL/s in the patients with a body mass index of greater than 24 kg/m2 and 3.5 mL/s in the patients with a body mass index of 24 kg/m2 or lower. The contrast volume was determined by the flow rate and scan time. Image quality score and visualization of bypass grafts were evaluated. Subjective assessment of image quality for each coronary artery segment was determined using a 4-point grading scale by 2 reviewers, whereas objective evaluation of image quality was conducted by measuring the mean CT attenuation values (hounsfield unit [HU]) in terms of SD, contrast-noise ratio, and signal-noise ratio in the ascending aorta.
Results:
The mean (SD) contrast volume for the Iodixanol 270 and Iohexol 350 groups was 66.28 (12.00) and 64.98 (8.12) mL, respectively, with no significant difference (P = 0.57). The mean (SD) CT attenuation value in the Iodixanol 270 group was 414.72 (101.47), which was lower than in the Iohexol 350 group, which was 478.85 (108.73) (P = 0.01). The subjective image quality for the Iodixanol 270 group was superior to that for the Iohexol 350 group in the arterial graft vessels (P = 0.027), whereas there was no significant difference between the 2 groups in the venous graft vessels (P = 0.377). There was no significant difference in terms of SD of the ascending aorta, signal-noise ratio, and contrast-noise ratio between the 2 groups.
Conclusions:
Low-concentration iso-osmolar Iodixanol 270 provides image quality comparable with that of Iohexol 350, allowing diagnostic CCTA follow-up of patients with CABGs.
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Acute Coronary Syndrome III: Diagnostic Studies
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies III: Computed Tomography