Related Experiment Video
Updated: Apr 22, 2026

Use of a Percutaneous Ventricular Assist Device/Left Atrium to Femoral Artery Bypass System for Cardiogenic Shock
Published on: August 16, 2021
Ambulatory extra-aortic counterpulsation in patients with moderate to severe chronic heart failure
William T Abraham1, Sanjeev Aggarwal2, Sumanth D Prabhu3
1Division of Cardiovascular Medicine, The Ohio State University, Columbus, Ohio.
Objectives:
The study sought to assess feasibility, safety, and potential efficacy of a novel implantable extra-aortic counterpulsation system (C-Pulse) in functional class III and ambulatory functional class IV heart failure (HF) patients.
Background:
30% to 40% of HF patients suffer from poor functional status and quality of life (QoL) but are not in need of end-stage treatments. We undertook a multicenter single-arm study to assess the C-Pulse System in such patients.
Methods:
New York Heart Association (NYHA) functional class III or ambulatory functional class IV HF patients were eligible. Safety was assessed continuously through 12 months. Efficacy measurements included changes from baseline to 6 and 12 months in NYHA functional class, Minnesota Living with Heart Failure (MLWHF) and Kansas City Cardiomyopathy Questionnaire (KCCQ) scores, 6-min walk distance (6MWD), and exercise peak oxygen consumption (pVO2; 6 months only).
Results:
Twelve men and 8 women (56.7 ± 7 years, 34 to 71 years of age) with ischemic (n = 7) or nonischemic (n = 13) cardiomyopathy were implanted. There was no 30-day mortality and no neurological events or myocardial infarctions through 12 months. At 6 months, there were 3 deaths (1 device-related). One-year survival was 85%. At 6 months, C-Pulse produced improvements in NYHA functional class (3.1 ± 0.3 to 1.9 ± 0.7, p = 0.0005), MLWHF (63.6 ± 19.9 to 40.2 ± 23.2, p = 0.0005), and KCCQ scores (43.6 ± 21.1 to 65.6 ± 21.5, p = 0.0002), but not 6MWD (275.5 ± 64.0 to 296.4 ± 104.9, p = NS) or pVO2 (14.5 ± 3.6 to 13.1 ± 4.4, p = NS). Improvements continued at 12 months, with 6MWD change becoming statistically significant (336.5 ± 91.8, p = 0.0425).
Conclusions:
Use of C-Pulse in this population is feasible, appears safe, and improves functional status and QoL. A prospective, multicenter, randomized controlled trial is underway. (C-Pulse IDE Feasability Study-A Heart Assist System; NCT00815880).
More Related Videos
08:49Author Spotlight: Enhancing Graft Viability Assessment Through Quantitative Metrics and Innovative Reservoir Systems
Published on: August 2, 2024
06:10Utilizing Percutaneous Ventricular Assist Devices in Acute Myocardial Infarction Complicated by Cardiogenic Shock
Published on: June 12, 2021
Related Concept Videos
Heart Failure VI: Adjunct Therapies
Aortic Regurgitation IV: Nursing Management
Heart Failure V: Medical Management
Imbalances in Cardiac Output
CHF can occur due to the failure of either side of the heart. Left-side failure leads to pulmonary congestion—the right side continues to send...
Cardiomyopathy II: Dilated Cardiomyopathy
Heart Failure II: Pathophysiology