Cavopulmonary support with a microaxial pump for the failing Fontan physiology
Jiaquan Zhu1, Hideyuki Kato, Yaqin Y Fu
1From the *Division of Cardiovascular Surgery, The Labatt Family Heart Centre, The Hospital for Sick Children, University of Toronto, Toronto, Canada; †Cardiothoracic Surgery Department, Xinhua Hospital, Shanghai Jiaotong University, Shanghai, China; ‡Division of Cardiovascular Surgery, Toronto General Hospital; and §Department of Surgery, University of Toronto, Toronto, Canada.
Abstract:
The number of patients with the failing Fontan physiology is increasing. We tested a novel in situ microaxial pump (Impella) to support the failing atrio-pulmonary Fontan circulation in an acute pig model. A Fontan model was established in eight juvenile pigs by connecting the right atrium to the main pulmonary artery after tricuspid valve destruction. The Impella pump was inserted retrograde from the distal main pulmonary artery into the right atrium. Hemodynamics, blood gas, and echocardiographic data were compared among baseline, pure Fontan physiology (10 minutes), and mechanically assisted Fontan physiology (up to 12 hours). The Impella system generated a blood flow of 75-85 ml/kg/minute in six animals, and 55-65 ml/kg/minute in two animals. The mechanically assisted Fontan attained a significantly higher mean blood pressure (39.6 ± 7 vs. 24.7 ± 3.3 mm Hg, p < 0.01), lower central venous pressure (5 ± 2.4 vs. 12.8 ± 1.7 mm Hg, p < 0.01), and higher mixed venous saturation (60.4 ± 10.8 vs. 23.4 ± 8.4 mm Hg, p < 0.01) compared with pure Fontan physiology. Cardiac output and stroke volume were similar during baseline and mechanically assisted Fontan (p = not significant). This acute pig study demonstrated the feasibility of mechanical circulatory support in the failing Fontan physiology. The in situ microaxial pump maintained cardiac output while increasing blood pressure and reducing venous pressure.
More Related Videos
07:39Use of a Percutaneous Ventricular Assist Device/Left Atrium to Femoral Artery Bypass System for Cardiogenic Shock
Published on: August 16, 2021
06:10Utilizing Percutaneous Ventricular Assist Devices in Acute Myocardial Infarction Complicated by Cardiogenic Shock
Published on: June 12, 2021
Related Concept Videos
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Cardiopulmonary Resuscitation II: ACLS Airway Management
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Heart Failure VI: Adjunct Therapies
Treatment for Pulmonary Arterial Hypertension: Oxygen Therapy for Respiratory Failure
Oxygen therapy is vital in increasing and maintaining blood oxygen levels in PAH patients. As a result, it aids in reducing fatigue,...