Impact of an emergency medicine decision support and risk education system on computed tomography and magnetic
Tony J Carnevale1, Di Meng2, James J Wang2
1Kaiser Permanente Northwest Sunnyside Medical Center, Portland, Oregon.
Background:
Increasing computed tomography (CT) and magnetic resonance imaging (MRI) use in the emergency department (ED) over the last decade is well documented.
Objective:
Our aim was to assess the impact of an electronic decision support and risk education system (DS-RES) on CT/MRI use.
Methods:
We conducted an age-, sex-, and risk-adjusted analysis of CT/MRI use and ED and inpatient rebound rates before and after implementation in 2009 at a Kaiser Permanente Northwest medical center.
Results:
In the pre period, a total of 12,531 encounters occurred for unique patients within each of 10 chief complaint categories. In the post period, 16,864 total encounters occurred for unique patients within each chief complaint category, 11.4% of patients were at low risk and 24.8% and 63.8% were at medium and high risk, respectively. Adjusted CT/MRI use increased 1.1% (95% confidence interval [CI] 0%-2.3%) between pre and post periods. Among low-risk and medium-risk patients, CT/MRI use decreased by 5.0% (95% CI 2.5%-7.5%) and 10.4% (95% CI 7.9%-12.8%). Among patients at high risk, CT/MRI use increased by 3.9% (95% CI 2.5%-5.3%). The proportion of patients with a 3- or 7-day rebound to the ED or an inpatient facility decreased between pre and post periods by 1.4% (95% CI 0.7%-2.2%) and 0.7% (95% CI 0.2%-1.5%).
Conclusions:
DS-RES implementation did not decrease overall CT/MRI rates, but it was associated with a shift in use toward high-risk patients and less patient rebound to the ED and hospital. Further research is required to identify mechanisms underlying imaging utilization shifts.
Related Concept Videos
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Magnetic Resonance Imaging
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies for Cardiovascular System V: CT