Related Experiment Video
Updated: Apr 22, 2026

Evaluation of Fluid Overload by Bioelectrical Impedance Vectorial Analysis
Published on: August 17, 2022
Body composition measurements using bioimpedance analysis in peritoneal dialysis patients are affected by the
Seok Hui Kang1, Kyu Hyang Cho, Jong Won Park
1Division of Nephrology, Department of Internal Medicine, Yeungnam University Hospital, Daegu, Korea.
Abstract:
The presence of peritoneal dialysate when performing bioimpedance analysis may affect body composition measurements. The aim of this study was to evaluate the impact of dialysate on body composition measurements in Asians. Forty-one patients undergoing maintenance peritoneal dialysis in our hospital peritoneal dialysis unit were included in this study. Dialysate was drained from the abdomen prior to measurement, and bioimpedance analysis was performed using multi-frequency bioimpedance analysis, with each subject in a standing position (D-). Dialysate was then administered and the measurement was repeated (D+). The presence of peritoneal dialysate led to an increase in intracellular water (ICW), extracellular water (ECW), and total body water (D-: 20.33 ± 3.72 L for ICW and 13.53 ± 2.54 L for ECW; D+: 20.96 ± 3.78 L for ICW and 14.10 ± 2.59 L for ECW; P < 0.001 for both variables). Total and trunk oedema indices were higher in the presence of peritoneal dialysate. In addition, the presence of peritoneal dialysate led to an overestimation of mineral content and free fat mass (FFM) for the total body; but led to an underestimation of body fat (D-: 45.80 ± 8.26 kg for FFM and 19.30 ± 6.27 kg for body fat; D+: 47.51 ± 8.38 kg for FFM and 17.59 ± 6.47 kg for body fat; P < 0.001 for both variables). Our results demonstrate that the presence of peritoneal dialysate leads to an overestimation of FFM and an underestimation of fat mass. An empty abdomen is recommended when evaluating body composition using bioimpedance analysis.
More Related Videos
04:05Author Spotlight: Unveiling Prognostic Indicators in Heart Failure - The Role of Phase Angle and Bioelectrical Impedance Analysis
Published on: June 30, 2023
07:44Author Spotlight: Implementation of BIVA for Analyzing Disease Risk Factors in Patients with Low Body Cell Mass
Published on: July 14, 2023
Related Concept Videos
Peritoneal Dialysis III: Nursing Management
Peritoneal Dialysis I: Introduction and Procedure
Dialysis
Dialysis
Acute kidney injury develops suddenly and can be caused by pre-renal causes (e.g., hypovolemia, shock), intrinsic renal causes (e.g., acute tubular necrosis), or post-renal causes (e.g., urinary obstruction). In contrast, chronic renal failure progresses gradually over time and is often...
Peritoneal Dialysis II: Peritoneal Dialysis Systems and Complications
Hemodialysis III: Nursing Management